Acta Optica Sinica, Volume. 42, Issue 22, 2211004(2022)

High-Resolution Scintillation Screen with Double-Layer Structure Based on Crosstalk Suppression by Interface Total Reflection

Kang An1,2, Wenfang Li1,2, Xiaojiao Duan1,2, Yu Du3, Rifeng Zhou1,2, and Jue Wang1,2、*
Author Affiliations
  • 1Key Laboratory of Optoelectronic Technology & Systems, Ministry of Education, College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China
  • 2Industrial CT Non-destructive Testing Engineering Research Center of Ministry of Education, Chongqing 400044, China
  • 3Institute of Chemical Materials, China Academy of Engineering Physics, Mianyang 621000, Sichuan , China
  • show less
    References(21)

    [1] Wang X, Tu S J, Liu X et al. Advance and prospect for three-dimensional super-resolution microscopy[J]. Laser & Optoelectronics Progress, 58, 2200001(2021).

    [2] Lü H Y, Zou J, Zhao J T et al. Review on development of nano-computed tomography imaging technology[J]. Laser & Optoelectronics Progress, 57, 140001(2020).

    [3] Wang Z A, Liu B, Hua J W. Industrial CT detection technology of solid rocket motor based on standard sample comparison test[J]. Aerospace Materials & Technology, 50, 82-86(2020).

    [4] Gou Q Y, Xu S, Hao F et al. Full-scale pores and micro-fractures characterization using FE-SEM, gas adsorption, nano-CT and micro-CT: a case study of the Silurian Longmaxi Formation shale in the Fuling area, Sichuan Basin, China[J]. Fuel, 253, 167-179(2019).

    [5] Uesugi K, Hoshino M, Yagi N. Comparison of lens- and fiber-coupled CCD detectors for X-ray computed tomography[J]. Journal of Synchrotron Radiation, 18, 217-223(2011).

    [6] Wang Y, Liu D F, Xu Q F et al. Measurement and simulation of optical crosstalk of infrared detector modules[J]. Acta Optica Sinica, 36, 0404001(2016).

    [7] An K, Li W F, Duan X J et al. Fiber-coupled GAGG_Ce X-ray detector for high-resolution imaging[J]. Acta Optica Sinica, 42, 0111001(2022).

    [8] Chen H, Gu M, Liu X et al. Spatial resolution and light output of pixelated CsI(Tl) scintillation screen based on oxidized silicon micropore array template[J]. Journal of Instrumentation, 13, P07002(2018).

    [9] Tabata K, Ohtake R, Koike A et al. The high resolution scintillator type X-ray imaging detector with Si pixel collimator[J]. Proceedings of SPIE, 11369, 113690S(2020).

    [10] Tabata K, Ohtake R, Aoki T. High-spatial-resolution X-ray imaging by scintillator in silicon collimator[J]. Sensors and Materials, 32, 4037-4045(2020).

    [11] Liu S, Gu M, Chen H et al. Performance of pixelated CsI scintillation screen with hexagonal array arrangement prepared by vacuum melting injection method[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 903, 18-24(2018).

    [12] Chen Q W, Shi Y, Shi J L. The latest progress in ceramic scintillators research[J]. Journal of Materials Science and Engineering, 23, 128-132(2005).

    [13] Qu J J, Li L, Wu X L et al. Growth and scintillation properties of LuAG∶Ce crystal and LuAG∶Ce, Mg crystal[J]. Piezoelectrics & Acoustooptics, 41, 670-672, 678(2019).

    [14] Shao J M, Lu H N, Cai H. A point spread function model for X-ray imaging[J]. Acta Optica Sinica, 25, 1148-1152(2005).

    [15] Wang M Q, Cao L Z, Wu H C et al. Study on scattering corrections in flash radiography[J]. Atomic Energy Science and Technology, 46, 1382-1387(2012).

    [16] Zhou R F, Wang J, Han Z. Scattered correction in industrial X-ray computerized tomography[J]. Atomic Energy Science and Technology, 40, 450-452(2006).

    [17] Zhu Y, Qian S, Wang Z G et al. Scintillation properties of GAGG: Ce ceramic and single crystal[J]. Optical Materials, 105, 109964(2020).

    [18] Yang M T, Zhang L P. Total reflection X-ray fluorescence analysis[J]. Nuclear Electronics & Detection Technology, 22, 572-575(2002).

    [19] Yan C H, Whalen R T, Beaupré G S et al. Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction[J]. IEEE Transactions on Medical Imaging, 19, 1-11(2000).

    [20] Nagdive A, Dongre M, Makkar R. Design and simulation of NIR spectrometer using Zemax[C](2017).

    [21] Xu G Z[S]. Non-destructive testing radiographic testing image quality. Part V: measurement of image unsharpness with double-filament image quality indicator: GB/T 23901.5—2019(2019).

    Tools

    Get Citation

    Copy Citation Text

    Kang An, Wenfang Li, Xiaojiao Duan, Yu Du, Rifeng Zhou, Jue Wang. High-Resolution Scintillation Screen with Double-Layer Structure Based on Crosstalk Suppression by Interface Total Reflection[J]. Acta Optica Sinica, 2022, 42(22): 2211004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Mar. 15, 2022

    Accepted: May. 30, 2022

    Published Online: Nov. 7, 2022

    The Author Email: Wang Jue (wangjue@cqu.edu.cn)

    DOI:10.3788/AOS202242.2211004

    Topics