Acta Optica Sinica, Volume. 43, Issue 23, 2312001(2023)

Radiometric Calibration of Circular Variable Filter Type Spectroradiometer

Kunzhu Xiang1,2,3, Hailiang Shi1,2,3、*, Xiongwei Sun1,3, Feng Zhu1,3, Xianhua Wang1,2,3, and Hanhan Ye1,3
Author Affiliations
  • 1Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, Anhui , China
  • 2University of Science and Technology of China, Hefei 230026, Anhui , China
  • 3Key Laboratory of Optical Calibration and Characterization of Chinese Academy of Sciences, Hefei 230031, Anhui , China
  • show less
    References(17)

    [1] Zhang T, Dai X D, Chen C S et al. Measurement and calculation of infrared emissivity of target with non-full field of view[J]. Infrared and Laser Engineering, 44, 1-5(2015).

    [2] Yao K K, Wang H, Xu F et al. Application research of spectrometer in evaluation of infrared stealth effect of aero-engine[J]. Laser & Infrared, 50, 975-980(2020).

    [3] Zhao F Y, Zhang J Y, Wang L et al. Research on spectrum data analysis method of infrared flare[J]. Electro-Optic Technology Application, 37, 67-73(2022).

    [4] Wolfe W L, Zissis G J[M]. The infrared handbook(1978).

    [5] Wan S B. Research on absolute calibration technology of infrared radiometer[D], 17-20(2022).

    [6] Cabib D, Shapira S, Lavi M et al. SR 5000N: a new IR spectroradiometer implementation[J]. Proceedings of SPIE, 8541, 854116(2012).

    [7] Shi H L, Xiong W, Zou M M et al. Study on calibration method of spatial heterodyne spectrometer[J]. Spectroscopy and Spectral Analysis, 30, 1683-1687(2010).

    [8] Liu Z M, Gao M G, Liu W Q et al. Study on the method of FTIR spectrum non linear multiple point calibration[J]. Spectroscopy and Spectral Analysis, 28, 2077-2080(2008).

    [9] Kopolovich Z, Sapir E, Buckwald R A et al. Capabilities and applications of A computerized infrared spectroradiometer: the SR-5000[J]. Proceedings of SPIE, 0590, 211-221(1986).

    [10] Xing Z Q. Circular infrared variable filter[J]. Journal of Infrared and Millimeter Waves, 6, 141-146(1987).

    [11] Zhou J M, Wang S L. Visual-near infrared circular variable filters (CVF)[J]. Opto-Electronic Engineering, 12, 41-50(1985).

    [12] Cabib D, Orr H. Circular Variable Filters (CVF) at CI: progress and new performance[J]. Proceedings of SPIE, 8542, 85420U(2012).

    [13] Thelen A. Circularly wedged optical coatings I theory[J]. Applied Optics, 4, 977(1965).

    [14] Dennis Kitchens, 孟涛. 可见区圆形渐变滤光片[J]. 仪器制造, 29-33(1979).

         Kitchens D, Meng T. Visual circular variable filters[J]. Instrument Technique and Sensor, 29-33(1979).

    [15] Liu J Q, Han S L, Meng X et al. Radiometric calibration method of 2-14 μm infrared spectroradiometer[J]. Acta Optica Sinica, 39, 0212003(2019).

    [16] Wang H C, Liu H Y, Ying C P et al. Testing of infrared spectroradiometer using blackbody[C], 1289-1292(2016).

    Tools

    Get Citation

    Copy Citation Text

    Kunzhu Xiang, Hailiang Shi, Xiongwei Sun, Feng Zhu, Xianhua Wang, Hanhan Ye. Radiometric Calibration of Circular Variable Filter Type Spectroradiometer[J]. Acta Optica Sinica, 2023, 43(23): 2312001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Jan. 13, 2023

    Accepted: Mar. 12, 2023

    Published Online: Dec. 8, 2023

    The Author Email: Shi Hailiang (hlshi@aiofm.ac.cn)

    DOI:10.3788/AOS230473

    Topics