Infrared Technology, Volume. 47, Issue 6, 671(2025)

Research on Reliability Evaluation Model and Accelerated Aging Demonstration of Infrared Detector Assembly

Kai ZHANG1,2, Haiying LI1,2、*, Dong LIU1, Yingxu ZHANG1, Shouzhang YUAN1,2, Peiyuan LI1, Hongfu LI1, Wenli ZHAO1,2, Yun ZHA1, and Yusong ZHAO1
Author Affiliations
  • 1Kunming Institute of Physics, Kunming 650223, China
  • 2National Key Laboratory of Infrared Detection, Kunming 650223, China
  • show less
    References(25)

    [1] [1] Xavier Breniere, Alain Manissadjian, Michel Vuillermet, et al. Reliability optimization for IR detectors with compact cryo-coolers[C]//Proceedings of SPIE, 2005,5783: 212005.

    [2] [2] Brenire X, Tribolet P. Uniting IR detectors for tactical and space applications: a continuous cycle for reliability[C]//Proceedings of SPIE, 2009,7298: 72981V.

    [3] [3] Xavier Brenire, Laurent Rubaldo, Frederic Dupont. Sofradir's recent improvements regarding the reliability and performance of HgCdTe IR detectors[C]//Proceedings of SPIE, 2014,9070: 90702W.

    [4] [4] Mai M, Rhlich I, Schreiter A, et al. Performance and reliability enhancement of linear coolers[C]//Proceedings of SPIE, 2010,7660: 76602N.

    [5] [5] Breiter R, Wendler J, Lutz H. State-of-the-art MCT IR-modules with enhanced long term and cycle stability[C]//Proceedings of SPIE, 2012,8353: 83532L.

    [6] [6] Figgemeier H, Hanna S, Eich D. State-of-the-art MCT photodiodes for cutting-edge sensor applications by AIM[C]//Proceedings of SPIE, 2017,10177: 101771K.

    [7] [7] Heinrich Figgemeier, Christopher Ames, Rainer Breiter. Discovering the difference: bispectral MCT-based detectors by AIM[C]//Proceedings of SPIE, 2017,11002: 1100217

    [8] [8] Lutz H, Breiter R, Eich D, et al. Improved high performance MCT MWIR and LWIR modules[C]//Proceedings of SPIE, 2019,11002: 1100216.

    [9] [9] Holger Lutz, Rainer Breiter, Detlef Eich, et al. Towards high operating temperature and small pixel pitch MCT LWIR modules[C]//Proceedings of SPIE, 2022,12107: 121070T.

    [10] [10] Linder A, Furlong J, Malone N, et al. Lifetime evaluation of CMOS mixed signal devices[C]//Proceedings of SPIE, 2012,8511: 85110Y.

    [11] [11] Linder A, Eddie Glines. Lifetime evaluation of large format CMOS mixed signal infrared devices[C]//Proceedings of SPIE, 2015,9608: 96080Y.

    [12] [12] Richard M Rawlings. Ongoing life testing of the DRS infrared technologies flexure spring coolers[C]//Proceedings of SPIE, 2003,4820: 25-32.

    [13] [13] Dick Rawlings, Graham Averitt. A linear drive cryocooler for ultra-small infrared sensor systems[C]//Proceedings of SPIE, 2014,9070: 90702R.

    [14] [14] Thomas Shafer, Ramon Torres-Valladolid, Robert Burford, et al. High operating temperature (HOT) midwave infrared (MWIR) 6 μm pitch camera core performance and aturity[C]//Proc. of SPIE,.2022,12107: 121070V.

    [15] [15] Porat Z, Sne-Or A, Livni D. Reliability assessment procedure of crocoolers[C]//Proc. of SPIE, 1998,3436: 0277.

    [16] [16] Pundak N, Porat Z, Barak M, et al. Field reliability of Ricor microcoolers[C]//Proc. of SPIE, 2009,7298: 72983I.

    [17] [17] Sergey Riabzev, Ilan Nachman, Eli Levin, et al. RICOR K527 highly reliable linear cooler: applications and model overview[C]//Proc. of SPIE, 2017,10180: 101800G.

    [18] [18] Eli Levin, Amiram Katz, Zvi Bar Haim, et al. RICOR cryocoolers for HOT IR detectors from development to optimization for industrialized production[C]//Proc. of SPIE, 2017,10180: 1018005.

    [19] [19] Oron Ben David, Meir Carmiel, Victor Segal, et al. Ricor's advanced rotary cryocooler for HOT IR detectors[C]//Proc. of SPIE, 2019,11002: 110022M.

    [20] [20] Igor Vainshtein, Shlomi Baruch, Itai Regev, et al. Overview of RICOR's reliability theoretical analysis, accelerated life demonstration test results and verification by field data[C]//Proc. of SPIE, 2018,10626: 106260G.

    [21] [21] H van der Weijden, A Benschop, W van de Groep, et al. High-reliable linear cryocoolers and miniaturization developments at Thales Cryogenics[C]//Proc. of SPIE, 2010,7660: 76602O.

    [22] [22] W van de Groep, H van der Weijden, R van Leeuwen, et al. Update on MTTF figures for linear and rotary coolers of Thales Cryogenics[C]//Proc. of SPIE, 2012,8353: 83531S.

    [23] [23] Jean Yves Martin, Cdric Seguineau, Sbastien Van-Acker, et al. RMs1: qualification results of the rotary miniature Stirling cryocooler at Thales cryogenics[C]//Proc. of SPIE, 2017,10180: 1018008.

    [24] [24] Roel Arts, Daniel Willems, Tonny Benschop, et al. High-availability cryocooling for infrared sensors[C]//Proc. of SPIE, 2021,11741: 117410H.

    [25] [25] Vasse C, Lassalle S, Venzal S D. Improved reliability and flexibility of Thales RM2 rotary cooler[C]//Proc. of SPIE, 2023,12534: 125340B.

    Tools

    Get Citation

    Copy Citation Text

    ZHANG Kai, LI Haiying, LIU Dong, ZHANG Yingxu, YUAN Shouzhang, LI Peiyuan, LI Hongfu, ZHAO Wenli, ZHA Yun, ZHAO Yusong. Research on Reliability Evaluation Model and Accelerated Aging Demonstration of Infrared Detector Assembly[J]. Infrared Technology, 2025, 47(6): 671

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Apr. 3, 2024

    Accepted: Jul. 3, 2025

    Published Online: Jul. 3, 2025

    The Author Email: LI Haiying (kryolhy@163.com)

    DOI:

    Topics