Chinese Journal of Lasers, Volume. 46, Issue 8, 0804004(2019)

Measuring Refractive Index of Transparent Plate by Low-Coherent Interference

Bo Gao*, Qiang Li, Ang Liu, and Liqun Chai
Author Affiliations
  • Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, Sichuan 621900, China
  • show less
    Figures & Tables(7)
    Schematic of measuring the refractive index for large parallel glass plate
    Optical path diagram after sample rotation
    Intensity modulation versus optical path difference between the reference and test paths
    Flow chart of the iteration algorithm for refractive index calculation
    Refractive index result fitted by Cauchy formula
    • Table 1. Measurement results of various parameters

      View table

      Table 1. Measurement results of various parameters

      ParameterL /mmL1 /mmL2 /mmi /(°)K9 index
      Value198.7546±0.00160.4543±0.001219.9015±0.00119.804±0.000561.506386
    • Table 2. Refractive index measured by V-prism

      View table

      Table 2. Refractive index measured by V-prism

      Wavelength /nm404.7435.8486.1546.1587.6656.3706.5
      Refractive index1.5296881.5261461.5218631.5182141.516311.5138461.512428
    Tools

    Get Citation

    Copy Citation Text

    Bo Gao, Qiang Li, Ang Liu, Liqun Chai. Measuring Refractive Index of Transparent Plate by Low-Coherent Interference[J]. Chinese Journal of Lasers, 2019, 46(8): 0804004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: measurement and metrology

    Received: Feb. 27, 2019

    Accepted: Apr. 19, 2019

    Published Online: Aug. 13, 2019

    The Author Email: Gao Bo (48491061@qq.com)

    DOI:10.3788/CJL201946.0804004