High Power Laser and Particle Beams, Volume. 37, Issue 7, 075003(2025)

Field-line coupling characteristics of relay protection device under strong electromagnetic pulse

Dingding Yao1, Weidong Zhang1, Long Jin2, Zexin Zhou2, and Guanglong Zhou1
Author Affiliations
  • 1State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China
  • 2National Key Laboratory of Power Grid Safety, China Electric Power Research Institute, Beijing 100192, China
  • show less
    References(20)

    [2] Qin Feng, Wang Xutong, Chen Wei. Transient response and failure mechanism of distribution transformer under high-altitude electromagnetic pulse[J]. Proceedings of the CSEE, 43, 6924-6932(2023).

    [3] Qiu Aici, Bie Zhaohong, LI Gengfeng. HEMP threat and development strategy of resilient power system[J]. Modern Applied Physics, 12, 030101(2021).

    [4] Li Xiangchao, Wang Xianchao. Characteristics of power transmission cable coupled strong electromagnetic pulse[J]. Insulators and Surge Arresters, 1-11(2024).

    [5] [5] Paul C R. Analysis of multiconduct transmission lines[M]. Yang Xiaoxian, Zheng Tao, trans. 2nd ed. Beijing: China Electric Power Press, 2013: 1372

    [9] Xi Zhihao, Liang Tao, Xie Yanzhao. Field-to-line coupling model for insulated wiring bundle based on time-domain BLT equation[J]. High Voltage Engineering, 50, 758-764(2024).

    [11] Hu Rong, Cui Xiang, Chen Weijiang. A method of finite difference time domain combined with electromagnetic field and transmission lines[J]. Journal of North China Electric Power University, 42, 1-7,30(2015).

    [12] Li Baozhong, He Jinliang, Zhou Hui. Eletromagnetic interference of transmisssion line in HEMP environment[J]. High Voltage Engineering, 35, 2753-2758(2009).

    [14] Zhang Weidong, Chen Peilong, Chen Weijiang. Measurement and simulation of disturbance voltage generated by VFTO in UHV GIS substation on the secondary cables[J]. Proceedings of the CSEE, 33, 187-196(2013).

    [15] Chen Weijiang, Zhao Jun, Bian Kai. Research progress on transient electromagnetic disturbance due to switching operations in GIS substation[J]. Proceedings of the CSEE, 39, 4935-4948(2019).

    [16] Pan Xiaodong, Wei Guanghui, Wan Haojiang. Research on several test issues of electromagnetic radiation susceptibility for electronic equipment[J]. High Power Laser and Particle Beams, 32, 073002(2020).

    [17] Pan Xiaodong, Wei Guanghui, Lu Xinfu. Test method of using differential mode directional injection as a substitute for high intensity electromagnetic pulse radiation[J]. Chinese Journal of Radio Science, 32, 151-160(2017).

    [18] Huang Hui. Design strategy of electromagnetic anti-jamming for hardware system of microcomputer relay protection[J]. Power System Protection and Control, 38, 220-224(2010).

    [19] Zheng Yuping, Lyu Pengfei, Li Bin. Problems faced by relay protection in new power system and their solution ideas[J]. Automation of Electric Power Systems, 47, 3-15(2023).

    [20] [20] GBT 17799.52012, Electromagic compatibility (EMC)Generic stardsHEMP immunity f indo equipment[S]

    Tools

    Get Citation

    Copy Citation Text

    Dingding Yao, Weidong Zhang, Long Jin, Zexin Zhou, Guanglong Zhou. Field-line coupling characteristics of relay protection device under strong electromagnetic pulse[J]. High Power Laser and Particle Beams, 2025, 37(7): 075003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jan. 15, 2025

    Accepted: Jun. 3, 2025

    Published Online: Jul. 18, 2025

    The Author Email:

    DOI:10.11884/HPLPB202537.250014

    Topics