Chinese Optics Letters, Volume. 19, Issue 11, 111701(2021)

Review of photoacoustic imaging for microrobots tracking in vivo [Invited] On the Cover

Dengfeng Li, Yachao Zhang, Chao Liu, Jiangbo Chen, Dong Sun*, and Lidai Wang**
Author Affiliations
  • Department of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China
  • show less
    Figures & Tables(13)
    Schematic summary of microrobots tracking in vivo based on PAI.
    In vivo PAI from organelles to organism. (a) A typical tubular-shaped mitochondrion in mouse embryonic fibroblasts[28]. (b) Capillary beds and RBCs in mouse ears[29]. (c) Heartbeat-encoded arterial network mapping of a 27-year-old healthy female volunteer’s breast cross-sectional image[30]. (d) Complete maximum intensity projection (MIP) PA image of the hand[31].
    Multi-contrast and multi-parameter PAI. (a) Labeled tumor and surrounding vascular vessels[33]. (b) Oxygen saturation (sO2) in mouse ear[29]. (c) BF in mouse ears[34]. (d) Labeled lymphatic and blood vessels[35].
    PAI-trackable magnetic microswimmers. Reproduced with permission from Ref. [42].
    In vivo US/PACT imaging of the liver and kidney. (a) US image, bipolar PA image, and unipolar PA image at the cross section of the liver (P1) and kidney (P2); arrow 1 denotes the tracked and recorded artery blood vessel position. (b) Respiration motion time interval estimation according to the correlation coefficient calculation. (c) PA amplitude changing as a function of time at the position marked by an arrow [P1 in (a)] and its corresponding spectral analysis. Reproduced with permission from Ref. [60].
    Microrobotic system guided by PACT in vivo. (a) Microrobots in the mouse with PA excitation and generation. (b) PACT imaging setup. (c) Enteric coating protection in the stomach. (d) CW NIR laser irradiation for micromotor release in the intestine. (e) Microrobots propulsion to the therapy region. (f) Dynamics evaluation of PACT-guided microrobots movement in the intestine. (g) Movement displacement caused by the microrobots migration. (h) Movement displacement caused by respiration. (i) Speed comparison of microrobots migration and the respiration-induced movement. Reproduced with permission from Ref. [70].
    Microrobots imaging and navigation using developed PACT/US dual-modal system. (a) Comparison of PA signal amplitude in the left lateral lobe with and without injection microrobots clusters. The microrobots were injected through the portal vein, and the PA images were overlayed on the US images. (b) PA/US imaging guiding microrobots in the inferior vena cava of the mouse. Reproduced with permission from Ref. [23].
    PAI of a single microrobot in blood. (a) Optical resolution PA system. (b) High-resolution PA tracking of a single micro-rocket in the blood vessel model. Reproduced with permission from Ref. [22].
    Voice-coil-driven fast-scanning OR-PAM. (a) Schematic of the system. (b) Snapshots of single RBCs releasing oxygen in a mouse brain. (c) sO2 images without continuous visual stimulation. (d) sO2 images with 1 Hz continuous optical flashing stimulations on the left mouse eye. Reproduced with permission from Ref. [83].
    Polygon-scanning fast OR-PAM. (a) Schematic of the system. (b) sO2 image of the mouse ear; C-scan time is ∼5 s. (c) Flowing iron particle tracking. Reproduced with permission from Ref. [85].
    Single-breath-hold PACT system for breast cancer diagnosis and screening. (a) Perspective cut-away view of patient bed and optical components of the system. (b) Data acquisition components of the system. Four sets of 128-channel data acquisition systems were mapping a custom-built 512-element ring-array transducer. Reproduced with permission from Ref. [30].
    • Table 1. Scanning Speed and Range of Fast-Scanning PAM Systems

      View table
      View in Article

      Table 1. Scanning Speed and Range of Fast-Scanning PAM Systems

      MethodsB-scan Rate (Hz)B-scan Range (mm)
      Galvanometer[79]1800/1000.1/6
      Water-immersible galvanometer[50,86]500>2.4
      Voice-coil[84]40∼5
      Single-axis water-immersible MEMS[46]400>3
      Dual-axis water-immersible MEMS[87]59
      Polygon mirror[85,88]∼500∼12
    • Table 2. Summary of PAI Systems in the Review for Microrobots Tracking

      View table
      View in Article

      Table 2. Summary of PAI Systems in the Review for Microrobots Tracking

      PAI System & TechniquesResolutionImaging DepthAdvantagesApplications
      SIP-PACT[43,70]125 µm48 mmWhole-body dynamics and function imaging for small animalsReal-time tracking of microrobots in vivo
      OR-PAM[22]3.2 µm1 mmHigh-resolution imagingHigh-resolution microrobots tracking in epidermal blood vessels or tissue
      Polygon-scanning fast OR-PAM[85]∼6.3 µm0.97 mmFast and high-resolution imagingReal-time and high-resolution microrobots tracking in the epidermis
    Tools

    Get Citation

    Copy Citation Text

    Dengfeng Li, Yachao Zhang, Chao Liu, Jiangbo Chen, Dong Sun, Lidai Wang, "Review of photoacoustic imaging for microrobots tracking in vivo [Invited]," Chin. Opt. Lett. 19, 111701 (2021)

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Biophotonics

    Received: Mar. 30, 2021

    Accepted: May. 14, 2021

    Published Online: Sep. 6, 2021

    The Author Email: Dong Sun (medsun@cityu.edu.hk), Lidai Wang (lidawang@cityu.edu.hk)

    DOI:10.3788/COL202119.111701

    Topics