Acta Photonica Sinica, Volume. 54, Issue 5, 0532001(2025)

Precision Machining of ITO Film by Femtosecond Pulse Train Output from Fabry-Perot Cavity

Chongzhou LI1, Peiyao WANG2, Mingquan LONG1, Yufeng XU1, Ruozhong HAN1, and Tianqing JIA1、*
Author Affiliations
  • 1State Key Laboratory of Precision Spectral Science and Technology,East China Normal University,Shanghai 200241,China
  • 2National Institute of Metrology,Beijing 100029,China
  • show less
    Figures & Tables(17)
    Schematic diagram of femtosecond laser pulse train generator based on F-P cavity
    Generation of the pulse train by the F-P cavity
    Indium content at different regions on processed ITO films
    SEM measurement area corresponding to Fig.3(b),(c)and(d)
    SEM images of etched lines at different scanning speeds(F = 0.2 J/cm2)
    SEM images of etched lines at different scanning speeds(F = 0.49 J/cm2)
    Comparison of LER of lines etched by Gaussian light and pulse train
    AFM images of cross sections of etched lines at different sub-pulse intervals(F = 0.49 J/cm2,v = 0.2 mm/s)
    SEM images of etched lines at different sub-pulse intervals(F = 0.49 J/cm2,v = 0.2 mm/s)
    Variation diagram of average width and inclination angle in Table 1
    SEM images of etched lines at different laser fluence(v = 0.2 mm/s,∆t = 150 ps)
    AFM images of cross sections of etched lines at different laser fluence(v = 0.2 mm/s,∆t = 150 ps)
    SEM images of rows of lines with different spatial period
    SEM images of rows of lines with different spatial period
    Dimensional parameter diagram and SEM image of complex wire
    Measurement of wire width
    • Table 1. Corresponding values of each image in Fig. 8

      View table
      View in Article

      Table 1. Corresponding values of each image in Fig. 8

      Fig.8(a)Fig.8(b)Fig.8(c)Fig.8(d)
      Average depth/nm179.46181.2186.26188.05
      Top width/μm1.701.541.451.41
      Bottom width/μm1.111.020.950.93
      Width difference/μm0.590.520.50.48
      Inclination angle31.31°34.81°36.69°38.07°
    Tools

    Get Citation

    Copy Citation Text

    Chongzhou LI, Peiyao WANG, Mingquan LONG, Yufeng XU, Ruozhong HAN, Tianqing JIA. Precision Machining of ITO Film by Femtosecond Pulse Train Output from Fabry-Perot Cavity[J]. Acta Photonica Sinica, 2025, 54(5): 0532001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Ultrafast Optics

    Received: Nov. 25, 2024

    Accepted: Jan. 26, 2025

    Published Online: Jun. 18, 2025

    The Author Email: Tianqing JIA (tqjia@phy.ecnu.edu.cn)

    DOI:10.3788/gzxb20255405.0532001

    Topics