High Power Laser Science and Engineering, Volume. 8, Issue 2, 02000e26(2020)
Clean source of soft X-ray radiation formed in supersonic Ar gas jets by high-contrast femtosecond laser pulses of relativistic intensity
Fig. 1. (a) General scheme of the experimental setup. (b) Central cross-section of the nozzle. (c) Coordinates of the focal spot position.
Fig. 2. (a), (b) X-ray emission spectra and (c)–(e) corresponding electron measurement results detected in -direction (laser propagation axis) for the following experimental conditions: inlet gas pressure –
, laser energy –
, laser beam is focused at the center of Ar gas jet, perpendicularly to gas flow
-axis at the distance from nozzle outlet (a), (c), (d)
and (b), (e)
.
Fig. 3. X-ray emission spectra of Ar plasma depend on – laser focusing point displacement from nozzle outlet
, measured at fixed parameters: inlet Ar gas pressure –
, laser energy on target –
, laser pulse duration –
, laser contrast –
in diagnostic direction (a)
, (b)
and (c)
. Note that, the X-ray intensity on axis of ordinates is given in absolute values.
Fig. 4. (a) Dependence of the X-ray emission registered in the -direction on
(the distance from the nozzle outlet to the laser focusing point). Simulated spectra obtained by the radiational–collisional code PrismSpect for different electron temperatures
, fixed atomic densities and the hot electrons fraction of 0.1% with the temperature
are shown by the red lines. (b) X-ray yield per laser shot of photons with the energy of
versus distance from the nozzle throat
for diagnostic directions
,
and
. (c) Results of hydrodynamic calculations for the gas jet density profile for the slit nozzle MS05-10-166[24] and different
.
Fig. 5. Dependence of Ar plasma X-ray emission spectra on the laser pulse energy . The X-ray emission was observed in (a)
-direction, (b)
-direction and (c)
-direction. The X-ray emission spectra have been measured under the following experimental conditions: entry pressure of the Ar gas jet –
, the distance from nozzle outlet to laser focus position –
, laser pulse duration –
, laser pulse contrast –
.
Fig. 6. (a) The comparison of the Ar plasma X-ray emission spectra measured for two different laser pulse energies and
and kinetic modeling carried out with the PrismSpect. The calculations have been done for the fixed parameters: the ion density of the Ar gas jet –
, fraction 0.1% of hot electrons with
. (b) Yield of X-ray photons with the energies
versus the incident laser pulse energy.
Fig. 7. (a) X-ray emission spectra of Ar plasma; (b) X-ray photons yield – at the energy range
versus the laser pulse duration –
; (c) X-ray photons yield –
in the energy range
versus entry Ar gas pressure –
, observed for the laser focusing position
for diagnostic directions
,
and
toward the axis of the laser propagation direction.
Get Citation
Copy Citation Text
Maria Alkhimova, Sergey Ryazantsev, Igor Skobelev, Alexey Boldarev, Jie Feng, Xin Lu, Li-Ming Chen, Sergey Pikuz. Clean source of soft X-ray radiation formed in supersonic Ar gas jets by high-contrast femtosecond laser pulses of relativistic intensity[J]. High Power Laser Science and Engineering, 2020, 8(2): 02000e26
Category: Research Articles
Received: Dec. 18, 2019
Accepted: Apr. 20, 2020
Published Online: Jun. 29, 2020
The Author Email: