Piezoelectrics & Acoustooptics, Volume. 46, Issue 4, 496(2024)
Design and Fabrication of High-Frequency PMUT Array Based on an ScAlN Thin Film
[1] [1] POWLES A E J,MARTIN D J,WELLS I T P,et al.Physics of ultrasound[J]. Anaesthesia & Intensive Care Medicine, 2018, 19(4): 202-205.
[2] [2] PRZYBYLA R,IZYUMIN I,KLINE M,et al. An ultrasonic rangefinder based on an AlN piezoelectric micromachined ultrasound transducer[J].Sensors,2010:2417-2421.
[3] [3] JI W, LIU L, XING Z, et al. Total-focus ultrasonic imaging of defects in solids using a PZT piezoelectric micromachined ultrasonic transducer array[J].IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2020, 68(4): 1380-1386.
[4] [4] CHENG C Y, DANGI A, REN L, et al. Thin film PZT-based PMUT arrays for deterministic particle manipulation[J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2019, 66(10):1606-1615.
[5] [5] CHEN Y Q,LI Y X,CHEN Y,et al.Large-scale and high-density pMUT array based on isolated Sol-Gel PZT membranes for fingerprint imaging[J].Journal of The Electrochemical Society, 2017, 164(7): B377.
[6] [6] WANG Y F, YANG Y, REN T L, et al. Ultrasonic transducer array design for medical imaging based on MEMS technologies[C]∥Yantai,China:2010 3rd International Conference on Biomedical Engineering and Informatics, IEEE, 2010, 2: 666-669.
[7] [7] SHAO Z, PENG Y, PALA S, et al. 3D ultrasonic object detections with> 1 meter range[C]∥Gainesville,FL, USA:2021 IEEE 34th International Conference on Micro Electro Mechanical Systems (MEMS),IEEE, 2021: 386-389.
[8] [8] ZHU Q, CHEN T, LIU H,et al.An AlN-based piezoelectric micro-machined ultrasonic transducer (pMUT) array[C]∥Sendai, Japan:2016 IEEE 16th International Conference on Nanotechnology (IEEE-NANO),IEEE,2016: 731-734.
[10] [10] LAMBERTI N, CALIANO G,IULA A,et al.A high frequency cMUT probe for ultrasound imaging of fingerprints[J]. Sensors and Actuators A:Physical,2011, 172(2): 561-569.
[11] [11] MURALT P, LEDERMANN N, PABOROWSKI J,et al. Piezoelectric micromachined ultrasonic transducers based on PZT thin films[J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control,2005,52(12): 2276-2288.
[12] [12] SANO K,KARASAWA R,YANAGITANI T.ScAlN thick-film ultrasonic transducer in 40-80 MHz[J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2018, 65(11): 2097-2102.
[13] [13] IAGNOCCO A, CECCARELLI F, PERRICONE C,et al. The role of ultrasound in rheumatology[C]∥ Italy:Seminars in Ultrasound, CT and MRI. WB Saunders,2011, 32(2): 66-73.
[14] [14] DING H, AKHBARI S, EOVINO B E, et al. Ultrasonic imaging of muscle-like phantoms using bimorph pmuts toward wearable muscle disorder diagnostics[C]∥Belfast, UK:2018 IEEE Micro Electro Mechanical Systems (MEMS). IEEE, 2018: 396-399.
[15] [15] QU M, DING H, LI D, et al. Imaging of simulated muscle based on single chip of AlN piezoelectric micromachined ultrasonic transducer[J]. Journal of Micromechanics and Microengineering,2022,32(7): 075003.
[16] [16] LU Y, HEIDARI A, HORSLEY D A. A high fillfactor annular array of high frequency piezoelectric micromachined ultrasonic transducers[J]. Journal of Microelectromechanical Systems, 2014, 24(4): 904-913.
[17] [17] KIM J, LI S, KASOJI S, et al. Phantom evaluation of stacked-type dual-frequency 1-3 composite transducers: A feasibility study on intracavitary acoustic angiography[J]. Ultrasonics, 2015, 63: 7-15.
[18] [18] LI S,TIAN J, JIANG X. A micromachined Pb(Mg1/3Nb2/3) O3-PbTiO3 single crystal composite circular array for intravascular ultrasound imaging[J]. Journal of Engineering and Science in Medical Siagnostics and Therapy, 2019, 2(2): 021001.
[19] [19] SAVOIA A S, CASAVOLA M, BONI E, et al. Design,fabrication, characterization, and system integration of a 1-D PMUT array for medical ultrasound imaging[C]∥Xi’an,China:2021 IEEE International Ultrasonics Symposium (IUS), IEEE, 2021: 1-3.
[20] [20] SAVOIA A S, MATERA R, QUAGLIA F, et al. A feasibility study of a PMUT-based wearable sensor for the automatic monitoring of carotid artery parameters[C]∥Xi’an, China:2021 IEEE International Ultrasonics Symposium (IUS), IEEE, 2021: 1-4.
[21] [21] KIM J N, LIU T, JACKSON T N,et al.10 MHz thinfilm PZT-based flexible PMUT array:Finite element design and characterization[J]. Sensors, 2020, 20(15): 4335.
[22] [22] MURALT P.PZT thin films for microsensors and actuators: Where do we stand? [J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control,2000, 47(4): 903-915.
[23] [23] DUBOIS M A, MURALT P.Measurement of the effective transverse piezoelectric coefficient e31, f of AlN and Pb (Zrx , Ti1-x )O3 thin films[J]. Sensors and Actuators A: Physical, 1999, 77(2): 106-112.
[24] [24] MERTIN S,HEINZ B,RATTUNDE O, et al. Piezoelectric and structural properties of c-axis textured aluminium scandium nitride thin films up to high scandium content[J]. Surface and Coatings Technology,2018, 343: 2-6.
[25] [25] SZABO T L, LEWIN P A. Ultrasound transducer selection in clinical imaging practice[J]. Journal of Ultrasound in Medicine, 2013, 32(4): 573-582.
[26] [26] CHEN X, LIU C, YANG D, et al. Highly accurate airflow volumetric flowmeters via pMUTs arrays based on transit time[J]. Journal of Microelectromechanical Systems, 2019, 28(4): 707-716.
[27] [27] LIAO W J, REN T L, YANG Y, et al. Novel device design for an ultrasonic ranging system[J]. Integrated Ferroelectrics, 2009, 105(1): 53-65.
[28] [28] JIANG X, LU Y, TANG H Y, et al. Monolithic ultrasound fingerprint sensor[J]. Microsystems & Nanoengineering, 2017, 3(1): 1-8.
Get Citation
Copy Citation Text
TA Guifeng, LIU Jianhe, LI Jiadong, YAO Shutao, LIU Haojie, MIAO Bin, SHANG Wenling, TAO Jinyan. Design and Fabrication of High-Frequency PMUT Array Based on an ScAlN Thin Film[J]. Piezoelectrics & Acoustooptics, 2024, 46(4): 496
Received: Apr. 23, 2024
Accepted: --
Published Online: Sep. 18, 2024
The Author Email: