Chinese Journal of Lasers, Volume. 49, Issue 5, 0507202(2022)

Review on Dynamic Scattered Light Measurement in Full-Field Optical Coherence Tomography

Haoying Tian, Fengrui Tang, Wanrong Gao, and Yue Zhu*
Author Affiliations
  • School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu 210094, China
  • show less
    References(51)

    [1] Huang D, Swanson E A, Lin C P et al. Optical coherence tomography[J]. Science, 254, 1178-1181(1991).

    [2] Zheng J G[D]. Investigation of full-field OCT and morphological study of early mouse embryo development(2013).

    [3] Zhu Y[D]. Research on key technology in full-field optical coherence tomography(2018).

    [4] Dubois A, Vabre L, Boccara A C et al. High-resolution full-field optical coherence tomography with a Linnik microscope[J]. Applied Optics, 41, 805-812(2002).

    [5] Apelian C, Harms F, Thouvenin O et al. Subcellular metabolic contrast in living tissue using dynamic full field OCT (D-FFOCT) (Conference Presentation)[J]. Proceedings of SPIE, 9707, 97070T(2016).

    [6] Apelian C, Harms F, Thouvenin O et al. Dynamic full field optical coherence tomography: subcellular metabolic contrast revealed in tissues by interferometric signals temporal analysis[J]. Biomedical Optics Express, 7, 1511-1524(2016).

    [7] Scholler J, Groux K, Goureau O et al. Dynamic full-field optical coherence tomography: 3D live-imaging of retinal organoids[J]. Light, Science & Applications, 9, 140(2020).

    [8] Thouvenin O, Fink M, Boccara C. Dynamic multimodal full-field optical coherence tomography and fluorescence structured illumination microscopy[J]. Journal of Biomedical Optics, 22, 26004(2017).

    [9] Thouvenin O, Apelian C, Nahas A et al. Full-field optical coherence tomography as a diagnosis tool: recent progress with multimodal imaging[J]. Applied Sciences, 7, 236(2017).

    [10] Lee J, Wu W C, Jiang J Y et al. Dynamic light scattering optical coherence tomography[J]. Optics Express, 20, 22262-22277(2012).

    [11] Zhou Y W[D]. Research on diagnostic application and dynamic imaging method of full field optical coherence tomography(2019).

    [12] Wu M R[D]. Research on microscopic imaging system of structured light fluorescence illumination(2014).

    [13] Xiao K, Tian L J, Wang Z Y. Fast super-resolution fluorescence microscopy imaging with low signal-to-noise ratio based on deep learning[J]. Chinese Journal of Lasers, 47, 1007002(2020).

    [14] Liu Z, Luo Z W, Wang Z Y et al. Super-resolution fluorescence microscopy image reconstruction algorithm based on structured illumination[J]. Chinese Journal of Lasers, 48, 0307001(2021).

    [15] Mazlin V, Xiao P, Scholler J et al. Real-time non-contact cellular imaging and angiography of human cornea and limbus with common-path full-field/SD OCT[J]. Nature Communications, 11, 1868(2020).

    [16] Makhlouf H, Perronet K, Dupuis G et al. Simultaneous optically sectioned fluorescence and optical coherence microscopy with full-field illumination[J]. Optics Letters, 37, 1613-1615(2012).

    [17] Wang J, Léger J F, Binding J et al. Measuring aberrations in the rat brain by coherence-gated wavefront sensing using a Linnik interferometer[J]. Biomedical Optics Express, 3, 2510-2525(2012).

    [18] Zaitsev V Y, Gelikonov V M, Matveev L A et al. Recent trends in multimodal optical coherence tomography. I. polarization-sensitive OCT and conventional approaches to OCT elastography[J]. Radiophysics and Quantum Electronics, 57, 52-66(2014).

    [19] Dubois A[M]. Handbook of full-field optical coherence microscopy: technology and applications(2016).

    [20] Fercher A F, Hitzenberger C K, Sticker M et al. A thermal light source technique for optical coherence tomography[J]. Optics Communications, 185, 57-64(2000).

    [21] Beaurepaire E, Boccara A C, Lebec M et al. Full-field optical coherence microscopy[J]. Optics Letters, 23, 244-246(1998).

    [22] Vabre L, Dubois A, Boccara A C. Thermal-light full-field optical coherence tomography[J]. Optics Letters, 27, 530-532(2002).

    [23] Dubois A, Moneron G, Grieve K et al. Three-dimensional cellular-level imaging using full-field optical coherence tomography[J]. Physics in Medicine and Biology, 49, 1227-1234(2004).

    [24] Yang Y L[D]. Full-field optical coherence tomography(2008).

    [25] Zheng J G, Chen T Y, Wang C M et al. Label-free subcellular 3D live imaging of preimplantation mouse embryos with full-field optical coherence tomography[J]. Journal of Biomedical Optics, 17, 070503(2012).

    [26] Zheng J G, Huo T C, Tian N et al. Noninvasive three-dimensional live imaging methodology for the spindles at meiosis and mitosis[J]. Journal of Biomedical Optics, 18, 050505(2013).

    [27] Zhu Y, Gao W R, Zhou Y et al. Rapid and high-resolution imaging of human liver specimens by full-field optical coherence tomography[J]. Journal of Biomedical Optics, 20, 116010(2015).

    [28] Zhu Y, Gao W R. High-resolution full-field optical coherence tomography for biological tissue[J]. Chinese Journal of Lasers, 41, 0804002(2014).

    [29] Drexler W, Fujimoto J G[M]. Optical coherence tomography: technology and applications(2015).

    [30] Zhou Y W, Gao W R, Xu X Y. Imaging of human kidney and colon tissues with full-field optical coherence tomography[J]. Chinese Journal of Lasers, 45, 0607002(2018).

    [31] Scholler J. Motion artifact removal and signal enhancement to achieve in vivo dynamic full field OCT[J]. Optics Express, 27, 19562-19572(2019).

    [32] Moneron G, Boccara A C, Dubois A. Stroboscopic ultrahigh-resolution full-field optical coherence tomography[J]. Optics Letters, 30, 1351-1353(2005).

    [33] Dubois A, Moneron G, de Boccara C. Thermal-light full-field optical coherence tomography in the 1.2 μm wavelength region[J]. Optics Communications, 266, 738-743(2006).

    [34] Gao W R. Image contrast reduction mechanism in full-field optical coherence tomography[J]. Journal of Microscopy, 261, 199-216(2016).

    [35] de Martino A, Carrara D, Drevillon B et al. Full-field OCT with thermal light[J]. Proceedings of SPIE, 4431, 38-42(2001).

    [36] Yun S H, Tearney G J, de Boer J F et al. Motion artifacts in optical coherence tomography with frequency-domain ranging[J]. Optics Express, 12, 2977-2998(2004).

    [37] Sacchet D, Brzezinski M, Moreau J et al. Motion artifact suppression in full-field optical coherence tomography[J]. Applied Optics, 49, 1480-1488(2010).

    [38] Grieve K, Dubois A, Simonutti M et al. In vivo anterior segment imaging in the rat eye with high speed white light full-field optical coherence tomography[J]. Optics Express, 13, 6286-6295(2005).

    [39] Hrebesh M S, Dabu R, Sato M. In vivo imaging of dynamic biological specimen by real-time single-shot full-field optical coherence tomography[J]. Optics Communications, 282, 674-683(2009).

    [40] Choma M A, Yang C, Izatt J A. Instantaneous quadrature low-coherence interferometry with 3×3 fiber-optic couplers[J]. Optics Letters, 28, 2162-2164(2003).

    [41] Schausberger S E, Heise B, Bernstein S et al. Full-field optical coherence microscopy with Riesz transform-based demodulation for dynamic imaging[J]. Optics Letters, 37, 4937-4939(2012).

    [42] Na J, Choi W J, Choi E S et al. Image restoration method based on Hilbert transform for full-field optical coherence tomography[J]. Applied Optics, 47, 459-466(2008).

    [43] Yang F F, Gao W R, Zhu Y. Hilbert transform in full-field optical coherence tomography[J]. Laser & Optoelectronics Progress, 53, 111102(2016).

    [44] Walther J, Gaertner M, Cimalla P et al. Optical coherence tomography in biomedical research[J]. Analytical and Bioanalytical Chemistry, 400, 2721-2743(2011).

    [45] Leroux C E, Bertillot F, Thouvenin O et al. Intracellular dynamics measurements with full field optical coherence tomography suggest hindering effect of actomyosin contractility on organelle transport[J]. Biomedical Optics Express, 7, 4501-4513(2016).

    [46] Lancaster M A, Huch M. Disease modelling in human organoids[J]. Disease Models & Mechanisms, 12, dmm039347(2019).

    [47] Zhang P F, Zhang T W, Song W Y et al. Review of advances in ophthalmic optical imaging technologies from several mouse retinal imaging methods[J]. Chinese Journal of Lasers, 47, 0207003(2020).

    [48] Scholler J, Mazlin V, Thouvenin O et al. Probing dynamic processes in the eye at multiple spatial and temporal scales with multimodal full field OCT[J]. Biomedical Optics Express, 10, 731-746(2019).

    [49] Apelian C, Gastaud C, Boccara A C. Extracting relevant information for cancer diagnosis from dynamic full field OCT through image processing and learning[J]. Proceedings of SPIE, 10053, 100531H(2017).

    [50] Yang H P, Zhang S W, Liu P et al. Use of high-resolution full-field optical coherence tomography and dynamic cell imaging for rapid intraoperative diagnosis during breast cancer surgery[J]. Cancer, 126, 3847-3856(2020).

    [51] El-Sadek I A, Miyazawa A, Shen T W et al. Optical coherence tomography-based tissue dynamics imaging for longitudinal and drug response evaluation of tumor spheroids[J]. Biomedical Optics Express, 11, 6231(2020).

    Tools

    Get Citation

    Copy Citation Text

    Haoying Tian, Fengrui Tang, Wanrong Gao, Yue Zhu. Review on Dynamic Scattered Light Measurement in Full-Field Optical Coherence Tomography[J]. Chinese Journal of Lasers, 2022, 49(5): 0507202

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Sep. 23, 2021

    Accepted: Nov. 29, 2021

    Published Online: Mar. 9, 2022

    The Author Email: Zhu Yue (zhuyue@njust.edu.cn)

    DOI:10.3788/CJL202249.0507202

    Topics