Chinese Journal of Lasers, Volume. 49, Issue 5, 0507202(2022)

Review on Dynamic Scattered Light Measurement in Full-Field Optical Coherence Tomography

Haoying Tian, Fengrui Tang, Wanrong Gao, and Yue Zhu*
Author Affiliations
  • School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu 210094, China
  • show less
    Figures & Tables(3)
    Picture of dynamic multi-model imaging device PZT
    • Table 1. Ways to eliminate artifacts

      View table

      Table 1. Ways to eliminate artifacts

      Direction of researchSpecific method
      Acceleration of imaging speedUse of high-speed cameras
      Instantaneous phase shifting
      Algorithm improvementRiesz transform-based algorithms
      Hilbert transform-based image restoration technology
      Single-step phase-shifting demodulation algorithm based on Hilbert transform
      Singular value decomposition-based image filtering algorithms
    • Table 2. Research of D-FFOCT inprecision medicine

      View table

      Table 2. Research of D-FFOCT inprecision medicine

      TimeAuthorsSampleProcessApplicationParameter
      2016Apelian C,Harms F, Thouvenin O, et al.Cancerous cells in mouse intestineDiagnose cancerAxial resolution: 1 μm, imaging depth: 50100 μm
      Rat liver cellsIntroduced an inhibitor of the metabolic chainStudy pathological
      2016Leroux C E,Bertillot F,Thouvenin O, et al.Multicellular aggregates spheroidsIntroduced a selective inhibitor of class-II myosins (blebbistatin)Observe drug effect,diagnose cancerDepth resolution: 1 μm,isotropic resolution: 1 μm3 (at the central 625 nm wavelength), imaging depth: 60 μm
      2017Apelian C, Gastaud C, Boccara A C.Mouse intestinal cancerDiagnose cancerDepth resolution: 1 μm
      2017Thouvenin O,Apelian C,Nahas A, et al.A thick coronal section of fresh ex vivo rat brainReveal individual neuron shapes and sizesImaging depth: 100-200 μm
      Ex vivo subcutaneous pancreatic tumorDiagnose cancer
      Fresh rat liverEstablished more accurate angiogram and lymphogram,
      2019Scholler J,Mazlin V,Thouvenin O, et al.Macaque corneaCreating a wound in the epithelial layerFollowing in vitro sample evolution over long periods of timeTransverse resolution:0.4 μm, axial resolution: 1 μm, field of view: 390 μm×390 μm
      2020Scholler J,Groux K,Goureau O, et al.Retinal organoidsPathological studyCamera frame rate: 100 Hz,transverse resolution: 0.5 μm, axial resolution: 1.7 μm, field of view: 320 μm×320 μm
      2020Yang H P,Zhang S W, Liu P, et al.Breast and lymph node specimensDifferentiate benign and malignant cellsAxial resolution: 1 μm, imaging depth: 10 μm
      2020El-Sadek I A, Miyazawa A,Shen T W, et al.Breast adenocarcinoma (MCF7 cell line) spheroidsUse anti-cancer agent (paclitaxel)Diagnose cancer, drug response evaluationAxial resolution: 14 μm, lateral resolution: 19 μm
    Tools

    Get Citation

    Copy Citation Text

    Haoying Tian, Fengrui Tang, Wanrong Gao, Yue Zhu. Review on Dynamic Scattered Light Measurement in Full-Field Optical Coherence Tomography[J]. Chinese Journal of Lasers, 2022, 49(5): 0507202

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Sep. 23, 2021

    Accepted: Nov. 29, 2021

    Published Online: Mar. 9, 2022

    The Author Email: Zhu Yue (zhuyue@njust.edu.cn)

    DOI:10.3788/CJL202249.0507202

    Topics