Acta Optica Sinica, Volume. 41, Issue 1, 0130003(2021)

Research of High Sensitivity Cavity Ring-Down Spectroscopy Technology and Its Application

Wenqing Liu1、*, Xingping Wang1,2, Guosheng Ma1,3, Ying Liu1,3, Zhihao Zhao4, Xiang Li1, Hao Deng1, Bing Chen1、**, and Ruifeng Kan1
Author Affiliations
  • 1Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei, Anhui 230031, China
  • 2School of Engineering Science, University of Science and Technology of China, Hefei, Anhui 230027, China
  • 3School of Science Island, University of Science and Technology of China, Hefei, Anhui 230031, China
  • 4College of Information Science and Engineering, Northeastern University, Shenyang, Liaoning 110000, China
  • show less
    Figures & Tables(16)
    Schematic of atmospheric CO2 concentration measurement based on CRDS
    Results of long-time measurement of empty cavity. (a) Ring down measurement result; (b) result of Allen variance
    Spectral fitting of CO2 with concentration of 99×10-6 and its residual
    Schematic of high vacuum optical hygrometer based on CRDS[93]
    Integral absorption coefficients of the four absorption lines selected at dew-point temperature with different vapor pressures[93]
    Measurement results of trace water vapor absorption spectrum[93]
    Schematic of atmospheric methane measuring instrument based on CRDS[96]
    Results of continuous monitoring of atmospheric methane concentration[96]
    Methane vertical profile measurement system based on balloon-borne CRDS[89]. (a) System principle diagram; (b) physical diagram of the system
    The site of the second Qinghai-Tibet Plateau comprehensive scientific research test by captive balloon at Lulang[89]
    Spectral measurement and fitting results[89]. (a) At 5250 m altitude during the ascent; (b) at 5600 m altitude during the descent
    Measurement results of vertical distribution of methane concentration[89]. (a) During the ascent; (b) during the descent
    Schematic of in situ analysis system for deep-sea dissolved methane[88]
    3D design drawing of optical cavity[88]
    In the case of water vapor interference, the results of methane spectral fitting and its residual[88]. (a) Without water vapor spectral fitting; (b) with water vapor spectral fitting
    Compared with the measurement results of atmospheric methane concentration by the AIOFM methanometer and the commercial Piccaro methanometer[88]
    Tools

    Get Citation

    Copy Citation Text

    Wenqing Liu, Xingping Wang, Guosheng Ma, Ying Liu, Zhihao Zhao, Xiang Li, Hao Deng, Bing Chen, Ruifeng Kan. Research of High Sensitivity Cavity Ring-Down Spectroscopy Technology and Its Application[J]. Acta Optica Sinica, 2021, 41(1): 0130003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Spectroscopy

    Received: Nov. 19, 2020

    Accepted: Dec. 8, 2020

    Published Online: Feb. 23, 2021

    The Author Email: Liu Wenqing (wqliu@aiofm.ac.cn), Chen Bing (bchen@aiofm.ac.cn)

    DOI:10.3788/AOS202141.0130003

    Topics