Calibration method of the phase-shifting error for the topography measurement utilizing white light interferometric microscopy

Chao Zhang1,2, Qun Yuan3, Jiale Zhang3, Yi Ji2, Zhishan Gao3、*, and Junhua Yan1
Author Affiliations
  • 1Academy of Astronautics, Nanjing University of Aeronautics and Astronautics, Nanjing 210006, China
  • 2Key Laboratory for Advanced Optical Remote Sensing Technology of Beijing, Beijing Institute of Space Mechanics & Electricity, Beijing 100094, China
  • 3School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
  • show less

    Sequence of low coherence interferograms were captured during the vertical scanning of the interferometric microscope in the measurement procedure of the white light interferometric microscopy, and thus the topography of the surface under test was retrieved through determining the locations where the optical path difference (OPD) was zero in the envelope of the correlogram. The calculations of the topography for the micro-structures were composed of the vertical scanning interferometric (VSI) algorithm determining the coarse map and the phase-shifting interferometric (PSI) algorithm retrieving the fine map. Usually, the vertical scanning step was set as one eighth of the central wavelength, but the phase-shifting departures from π/2 inevitably due to the phase shifter error as well as the numerical aperture (NA) effect of the interferometric microscope. In this manuscript, the center-of-gravity solving of the visibility curves was adopted as VSI algorithm, and the 4M-frame method as well as the 7-frame method were both utilized as PSI algorithm respectively. The effect of the phase-shifting error on the topography measurement adopting the three above mentioned methods was discussed. Both theoretical derivations and simulation analysis demonstrate that the 7-frame method was insensitive to phase-shifting errors even under the low coherence illuminations. The fine phase error induced by phase-shifting error utilizing the 4M-frame method was by lucky coincides the form of the NA effect increasing the fringe spacing, and they were cancelled out during the transform from the fine phase to the topography. Therefore, adopting the center-of-gravity method as VSI algorithm and the 4M-frame method as the PSI algorithm, the phase-shifting errors arising from NA effect can be ignored, and the topography can be calibrated confronting the phase shifter error through measuring a certificated step standard in advance. A step height of 460 nm was measured utilizing the proposed method, and the topography demonstrate that it was both accurate and robustness.

    Tools

    Get Citation

    Copy Citation Text

    Chao Zhang, Qun Yuan, Jiale Zhang, Yi Ji, Zhishan Gao, Junhua Yan. Calibration method of the phase-shifting error for the topography measurement utilizing white light interferometric microscopy[J]. Infrared and Laser Engineering, 2022, 51(7): 20220050

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Photoelectric measurement

    Received: Nov. 20, 2021

    Accepted: Mar. 25, 2022

    Published Online: Dec. 20, 2022

    The Author Email:

    DOI:10.3788/IRLA20220050

    Topics