Acta Optica Sinica, Volume. 41, Issue 16, 1611003(2021)

Triple-Source Swinging Spiral CT Imaging Method for Security Inspection

Zhenzhen Pi1, Haijun Yu2,3, Lei Li1, Zhongjian Tian1, and Fenglin Liu1,2,3、*
Author Affiliations
  • 1State Key Laboratory of Mechanical Transmission, Chongqing University, Chongqing 400044, China
  • 2Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, China
  • 3Engineering Research Center of Industrial Computed Tomography Nondestructive Testing, Ministry of Education, Chongqing University, Chongqing 400044, China
  • show less
    References(25)

    [1] Cai Y F, Chen T Y, Wang J et al. Image noise reduction in computed tomography with non-local means algorithm based on adaptive filtering coefficients[J]. Acta Optica Sinica, 40, 0710001(2020).

    [2] Tian Z J, Yu H J, Wang L B et al. Orthogonal translation computed laminography[J]. Acta Optica Sinica, 40, 2211002(2020).

    [3] Wang S Y, Wu W W, Gong C C et al. Study of parallel translation computed laminography imaging[J]. Acta Optica Sinica, 38, 1211002(2018).

    [4] Wu W L, Li Y J, Sang B et al. Application of computed tomography in explosives detection[J]. Computerized Tomography Theory and Applications, 14, 24-32(2005).

    [5] Zheng J Z, Lu S D. Review of the application of computed tomography technology in safety inspection domain[J]. Computerized Tomography Theory and Applications, 21, 157-165(2012).

    [6] Ginat D T, Gupta R. Advances in computed tomography imaging technology[J]. Annual Review of Biomedical Engineering, 16, 431-453(2014).

    [7] Jin X, Zhang S Y, Li L et al. A dual-energy stationary CT system based on dual-plane scanning mode[J]. Computerized Tomography Theory and Applications, 29, 31-37(2020).

    [8] Wu W W, Yu H Y, Gong C C et al. Swinging multi-source industrial CT systems for aperiodic dynamic imaging[J]. Optics Express, 25, 24215-24235(2017).

    [9] Yu H J, Wu W W, Chen P et al. Image gradient L0-norm based PICCS for swinging multi-source CT reconstruction[J]. Optics Express, 27, 5264-5279(2019).

    [10] Grangeat P. Mathematical framework of cone beam 3D reconstruction via the first derivative of the radon transform[M]. ∥Herman G T, Louis A K, Natterer F. Mathematical methods in tomography. Lecture notes in mathematics. Heidelberg: Springer, 1497, 66-97(1991).

    [11] Tam K C, Samarasekera S, Sauer F. Exact cone beam CT with a spiral scan[J]. Physics in Medicine and Biology, 43, 1015-1024(1998).

    [12] Kudo H, Noo F, Defrise M. Quasi-exact filtered backprojection algorithm for long-object problem in helical cone-beam tomography[J]. IEEE Transactions on Medical Imaging, 19, 902-921(2000).

    [13] Defrise M, Noo F, Kudo H. A solution to the long-object problem in helical cone-beam tomography[J]. Physics in Medicine and Biology, 45, 623-643(2000).

    [14] Katsevich A. Theoretically exact FBP-type inversion algorithm for spiral CT[J]. ReCALL, 62, 1-3(2001).

    [15] Zou Y, Pan X C. Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT[J]. Physics in Medicine and Biology, 49, 941-959(2004).

    [16] Yu H Y, Zhao S Y, Ye Y B et al. Exact BPF and FBP algorithms for nonstandard saddle curves[J]. Medical Physics, 32, 3305-3312(2005).

    [17] Ye Y B, Zhao S Y, Yu H Y et al. A general exact reconstruction for cone-beam CT via backprojection-filtration[J]. IEEE Transactions on Medical Imaging, 24, 1190-1198(2005).

    [18] Yu H Y, Ye Y B, Zhao S Y et al. Local ROI reconstruction via generalized FBP and BPF algorithms along more flexible curves[J]. International Journal of Biomedical Imaging, 2006, 14989(2006).

    [19] Feldkamp L A, Davis L C, Kress J W. Practical cone-beam algorithm[J]. Journal of the Optical Society of America A, A1, 612-619(1984).

    [20] Wang G, Lin T H, Cheng P et al. A general cone-beam reconstruction algorithm[J]. IEEE Transactions on Medical Imaging, 12, 486-496(1993).

    [21] Grass M, Köhler T, Proksa R. 3D cone-beam CT reconstruction for circular trajectories[J]. Physics in Medicine and Biology, 45, 329-347(2000).

    [22] Grass M, Köhler T, Proksa R. Angular weighted hybrid cone-beam CT reconstruction for circular trajectories[J]. Physics in Medicine and Biology, 46, 1595-1610(2001).

    [23] Turbell H, Danielsson P E. The PI-, 1424-1425(1998).

    [24] Feng J, Yu H J, Wang S Y et al. Image-domain based material decomposition by multi-constraint optimization for spectral CT[J]. IEEE Access, 8, 155450-155458(2020).

    [25] Wu W W, Yu H J, Chen P J et al. DLIMD: dictionary learning based image-domain material decomposition for spectral CT[J]. Physics in Medicine and Biology, 65, 245006(2020).

    Tools

    Get Citation

    Copy Citation Text

    Zhenzhen Pi, Haijun Yu, Lei Li, Zhongjian Tian, Fenglin Liu. Triple-Source Swinging Spiral CT Imaging Method for Security Inspection[J]. Acta Optica Sinica, 2021, 41(16): 1611003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Feb. 1, 2021

    Accepted: Mar. 18, 2021

    Published Online: Aug. 12, 2021

    The Author Email: Liu Fenglin (liufl@cqu.edu.cn)

    DOI:10.3788/AOS202141.1611003

    Topics