Photonics Research, Volume. 5, Issue 2, 77(2017)

Experimental demonstration of transverse mode instability enhancement by a counter-pumped scheme in a 2  kW all-fiberized laser

Zebiao Li1,2, Zhihua Huang2, Xiaoyu Xiang2, Xiaobao Liang2, Honghuan Lin2, Shanhui Xu1,3,4, Zhongmin Yang1,3,4、*, Jianjun Wang2, and Feng Jing2
Author Affiliations
  • 1State Key Laboratory of Luminescent Materials and Devices and Institute of Optical Communication Materials, South China University of Technology, Guangzhou 510640, China
  • 2Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900, China
  • 3Guangdong Engineering Technology Research and Development Center of Special Optical Fiber Materials and Devices, South China University of Technology, Guangzhou 510640, China
  • 4Guangdong Provincial Key Laboratory of Fiber Laser Materials and Applied Techniques, South China University of Technology, Guangzhou 510640, China
  • show less
    Figures & Tables(10)
    Experimental setup.
    M2 factor variation of the co-pumped and counter-pumped schemes as a function of the output power.
    Spectra of the co-pumped and counter-pumped schemes with output power of nearly 2 kW.
    Coupling coefficients of the co-pumped and counter-pumped schemes along the 50/400 fiber. The reader can refer to Smith and Smith’s model for the fiber amplifier parameters [9].
    Coupling coefficients of the co-pumped and counter-pumped schemes along the 20/400 fiber.
    TMI threshold of the co-pumped amplifier as a function of initial HOM content.
    Output power of the co-pumped amplifier as a function of seed power.
    • Table 1. Parameters of Test Amplifier

      View table
      View in Article

      Table 1. Parameters of Test Amplifier

      dcore20 μmλs1064 nm
      ncore1.4575λp976 nm
      NAcore0.065hq1000  W/(m2K)
      NAclad0.46τ901 μs
      NYb6.52×1025  m3η1.2×105  K1
      σap1.77×1024  m2κ1.38 W/(Km)
      σep1.71×1024  m2ρ1.55×106  J/(Km3)
      σas6.40×1027  m2Ps20 W
      σes3.98×1025  m2RN1010  Hz1
    • Table 2. TMI Threshold Comparison I: with Identical Cladding Diameter

      View table
      View in Article

      Table 2. TMI Threshold Comparison I: with Identical Cladding Diameter

      FiberLength/mCo-Pump/WCounter-Pump/WBi-Pump/WER
      20/40015185347163195155%
      30/400811852356190399%
      50/40056581076109164%
    • Table 3. TMI Threshold Comparison II: with Identical Core Diameter

      View table
      View in Article

      Table 3. TMI Threshold Comparison II: with Identical Core Diameter

      FiberLength/mCo-Pump/WCounter-Pump/WBi-Pump/WER
      30/25036341018100360%
      30/400811852356190399%
      30/60015193349273326155%
    Tools

    Get Citation

    Copy Citation Text

    Zebiao Li, Zhihua Huang, Xiaoyu Xiang, Xiaobao Liang, Honghuan Lin, Shanhui Xu, Zhongmin Yang, Jianjun Wang, Feng Jing, "Experimental demonstration of transverse mode instability enhancement by a counter-pumped scheme in a 2  kW all-fiberized laser," Photonics Res. 5, 77 (2017)

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Nonlinear Optics

    Received: Nov. 24, 2016

    Accepted: Jan. 9, 2017

    Published Online: Oct. 10, 2018

    The Author Email: Zhongmin Yang (yangzm@scut.edu.cn)

    DOI:10.1364/PRJ.5.000077

    Topics