Acta Optica Sinica, Volume. 34, Issue 3, 330002(2014)
Study on the Performance Indexes of Spatial Heterodyne Spectrometer Influenced by Elements Tolerances
[1] [1] J M Harlander, F L Roesler. Spatial heterodyne spectroscopy: a novel interferometric technique for ground-based and space astronomy [C]. SPIE, 1990, 1235: 622-633.
[2] [2] F L Roesler, J M Harlander. Spatial heterodyne spectroscopy: interferometric performance at any wavelength without scanning [C]. SPIE, 1990, 1318: 234-243.
[3] [3] J G Cardon, C R Englert, J Harlander, et al.. SHIMMER on STS-112: development and proof of concept flight [C]. AIAA Space 2003 Conference and Exposition, Long Beach, California, 2003.
[4] [4] B W Smith, J Harlander. Imaging spatial heterodyne spectroscopy: theory and practice [C]. SPIE, 1999, 3698: 925-931.
[5] [5] J Harlander, F L Roesler, R J Reynolds, et al.. Differential field-widened spatial heterodyne spectrometer for investigations at high spectral resolution of the diffuse far-ultraviolet 1548-A emission line from the interstellar medium [C]. SPIE, 1993, 2006: 139-148.
[6] [6] S Watchorn, F L Roesle, J Harlander, et al.. Development of the spatial heterodyne spectrometer for VUV remote sensing of the interstellar medium [C]. SPIE, 2001, 4498: 284-295.
[7] [7] C R Englert, M H Stevens, D E Siskind, et al.. The Spatial Heterodyne Imager for Mesospheric Radicals (SHIMMER) on STPSat-1 [J]. J Geophys Res, 2010, 115(D20): D20306.
[8] [8] J M Harlander, F L Roesler, C R Englert, et al.. Robust monolithic ultraviolet interferometer for the SHIMMER instrument on STPSat-1 [J]. Appl Opt, 2003, 42(15): 2829-2834.
[9] [9] J Harlander, F L Roesler, J G Cardon, et al.. SHIMMER: a spatial heterodyne spectrometer for remote sensing of Earth′s middle atmosphere [J]. Appl Opt, 2002, 41(7): 1343-1352.
[10] [10] Yunlong Lin, Gordon Shepherd, Brain Solheim, et al.. Introduction to spatial heterodyne observations of water (SHOW) project and its instrument development [C]. ITSC-ⅩⅣ Proceedings Beijing, China, 2005, Poster.
[11] [11] Shi Hailiang, Xiong Wei, Li Zhiwei, et al.. Phase error correction of spatial heterodyne spectroscopy [J]. Acta Optica Sinica, 2013, 33(3): 0330003.
[13] [13] Ye Song, Xiong Wei, Wang Xinqiang, et al.. Correction of spatial heterodyne interferogram based on frequency domain analysis [J]. Acta Optica Sinica, 2013, 33(5): 0530001.
[15] [15] J Harlander, R J Reynolds, F L Roesler, et al.. Spatial heterodyne spectroscopy: laboratory tests of field-widened, multiple-order, and vacuum ultraviolet systems [C]. SPIE, 1992, 1743: 48-59.
[16] [16] Sun Ting, Xing Fei, You Zheng, et al.. Optical system error analysis of high accuracy star trackers [J]. Acta Optica Sinica, 2013, 33(3): 0323003.
[17] [17] Shi Hailiang, Fang Yonghua, Wu Jun, et al.. Study on spectral calibration of a novel interferometric spectrometer with super-resolution capability [J]. Acta Optica Sinica, 2012, 32(5): 0528002.
Get Citation
Copy Citation Text
Luo Haiyan, Shi Hailiang, Li Shuang, Xiong Wei, Hong Jin. Study on the Performance Indexes of Spatial Heterodyne Spectrometer Influenced by Elements Tolerances[J]. Acta Optica Sinica, 2014, 34(3): 330002
Category: Spectroscopy
Received: Sep. 2, 2013
Accepted: --
Published Online: Feb. 26, 2014
The Author Email: Haiyan Luo (luohaiyan@aiofm.ac.cn)