Acta Optica Sinica, Volume. 23, Issue 10, 1269(2003)

Recovery of Optical Parameters in Diffusive Media with a New Gated Photon Counting Method

[in Chinese], [in Chinese]*, and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less
    References(13)

    [1] [1] Bevilacqun F, Piguet D. In vivo local determination of tissue optical properties: applications to human brain. Appl. Opt., 1999, 38(22):4939~4950

    [2] [2] Arridge S. Optical tomography in medical imaging. Inverse Problems, 1999, 15(2):R41~R93

    [3] [3] Iftimia N, Jiang H. Quantitative optical image reconstruction of turbid media by use of direct current measurements. Appl. Opt., 2000, 39(28):5256~5261

    [4] [4] Schotland J. Continuous wave diffusion imaging. J. Opt. Soc. Am. (A), 1997, 14(1):275~279

    [6] [6] McBride T, Pogue B, Jiang S et al.. A parallel detection frequency domain near infrared tomography system for hemoglobin imaging of the breast in vivo. Rev. Sci. Instrum., 2001, 72(3):1817~1824

    [7] [7] Tromberg B, Svaassand L, Tsay T et al.. Properties of photon density waves in multiple scattering media. Appl. Opt., 1993, 32(4)607~616

    [8] [8] Pham T, Coquoz O, Fishkin J et al.. Broad bandwidth frequency domain instrument for quantitative tissue optical spectroscopy. Rev. Sci. Instrum., 2000, 71(N6):2500~2513

    [9] [9] Patterson M S, Chance B. Time resolved reflectance and transmittance for the non invasive measurement of tissue optical properties. Appl. Opt., 1989,28(12):2332~2336

    [10] [10] Ntziachristos V, Ma X, Chance B. Multichannel photon counting instrument for spatially resolved near infrared spectroscopy. Rev. Sci. Instrum., 1999, 70(1):193~201

    [11] [11] Haskell R, Svaasand L, Tsay T et al.. Boundary conditions for the diffusion equation in radiative transfer. Opt. Soc. Am. (A), 1994, 11(10):2727~2741

    [12] [12] O′Connor . Desmond V. Time Correlated Single Photon Counting. London, Orlando, Fla: Academic Press, 1984

    [13] [13] Becker Hickl GmbH. PMS 300:800 MHz Gated Photon Counter. Product Manual, 2000

    [14] [14] Becker Hickl GmbH. Time Correlated Single Photon Counting Modules. Product Manual, 2000

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese], [in Chinese], [in Chinese]. Recovery of Optical Parameters in Diffusive Media with a New Gated Photon Counting Method[J]. Acta Optica Sinica, 2003, 23(10): 1269

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Medical optics and biotechnology

    Received: Aug. 19, 2002

    Accepted: --

    Published Online: Jun. 27, 2006

    The Author Email: (qluo@hust.edu.cn)

    DOI:

    Topics