Infrared and Laser Engineering, Volume. 51, Issue 3, 20210722(2022)

Scattering interference suppression for single-pixel imaging reconstruction of biological tissues

Qiuping Lu, Yan Shi, Shengxin Dai, [in Chinese], Chunliu Zhao, Tianqi Zhao, Shangzhong Jin, and Haibin Niu
Author Affiliations
  • College of Optical and Electronic Technology, China Jiliang University, Hangzhou 310000, China
  • show less
    Figures & Tables(9)
    Division diagram of each functional module of single-pixel imaging system
    Reconstructed images under different algorithms. The algorithms used in (a)-(f) are the traditional second-order correlation algorithm, the traditional differential correlation algorithm, the calculated differential correlation algorithm, the random binary matrix OMP algorithm, the Hadamard matrix OMP algorithm and the Hadamard matrix TVAL3 algorithm, and the sampling rates are 0.1, 0.3, 0.6 and 1.0
    Image quality evaluation using different reconstruction algorithms at different sampling rates (PSNR, SSIM, TIME)
    Layout of active single-pixel imaging system based on DMD. (a) When there is no scattering medium; (b) When the scattering medium in detection path; (c) When the scattering medium inimaging path
    Comparison of the reconstruction effects of the two algorithms with non-scattering medium. (a) The first image recovered by CGI, and the last four images are recovered by TVAL3, with a sampling rate of 0.4-0.7; (b) PSNR and SSIM comparison of reconstructed image
    Performance of the light beam under the scattering of ground glass. (a)-(b) Intensity distribution comparison of structured light with or without scattering medium; (e) Uniform light passing through the object and scattering medium; The upper of (c1)-(c2) is a photo taken directly, and the below is a picture taken from the observation surface; (c3) Uniform light passing through the object and scattering medium; (d) Uniform light passing through the object
    Reconstructed image of penetrating scattering medium. (a) When the medium in imaging path, using CGI algorithm and TVAL3 algorithm, the latter sampling rate is 1-0.6, its peak signal-to-noise ratio and similarity. Comparison of (a) is in (b); (c) When scattering medium in detection path, and the comparison is in (d)
    Comparison of reconstruction time between CGI algorithm and TVAL3 algorithm in penetrating scattering media imaging
    • Table 1. Key device parameters in the experiment

      View table
      View in Article

      Table 1. Key device parameters in the experiment

      Key deviceParameter
      Light sourceWave length: 260-2500 nm
      Lens 1AR COATED 650-1050 nm, f=26 mm
      Lens 2f=100 mm
      Infrared filter800-2500 nm
      DMDOperating 350-2700 nm, 1024×768 pixel
      Projection lensf=35 mm
      Single point detectorOperating 800-1750 nm
      Focusing lensAR COATED 650-1050 nm, f=60 mm
    Tools

    Get Citation

    Copy Citation Text

    Qiuping Lu, Yan Shi, Shengxin Dai, [in Chinese], Chunliu Zhao, Tianqi Zhao, Shangzhong Jin, Haibin Niu. Scattering interference suppression for single-pixel imaging reconstruction of biological tissues[J]. Infrared and Laser Engineering, 2022, 51(3): 20210722

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical imaging

    Received: Sep. 30, 2021

    Accepted: --

    Published Online: Apr. 8, 2022

    The Author Email:

    DOI:10.3788/IRLA20210722

    Topics