Laser & Optoelectronics Progress, Volume. 56, Issue 7, 071201(2019)

Extraction Method of Line-Structured Light Stripe Center Based on Gauss-Lorenz Decomposition Peak Fitting

Taotao Li1,2、*, Feng Yang2, Shigeng Li1, and Yu He1
Author Affiliations
  • 1 College of Mechanical and Electronic Engineering, Pingxiang University, Pingxiang, Jiangxi 337055, China
  • 2 State Key Laboratory of Coal Resources and Safe Mining, China University of Mining and Technology (Beijing), Beijing 100083, China
  • show less
    Figures & Tables(14)
    Images of line-structured light stripes. (a) Approximately ideal reflection stripe; (b) strong diffuse reflection stripe; (c) strong specular reflection stripe; (d) weak reflection stripe
    Cross-sectional gray distributions at marked positions. (a) Sa; (b) Sb; (c) Sc; (d) Sd
    Results of single Gaussian fitting. (a) Approximately ideal light stripe; (b) strong specular reflection stripe
    Distribution curves of Gaussian and Lorentz components
    Flow chart of light stripe center extraction process based on G-L decomposition peak fitting
    Normalization of weak reflection light stripe image. (a) Before normalization; (b) after normalization
    Extraction of light stripe ROI. (a) Original image; (b) after Otsu initial extraction; (c) after removal of interference regions
    G-L fitting results of various types of light stripes. (a) Approximately ideal light stripe; (b) strong diffuse reflection stripe; (c) strong specular reflection stripe; (d) weak reflection stripe
    Four types of light stripe images used in contrast experiment. (a) Approximately ideal light stripe;(b) strong diffuse reflection stripe; (c) strong specular reflection stripe; (d) weak reflection stripe
    Extraction results of light stripe centers. (a) Approximately ideal light stripe; (b) strong diffuse reflection stripe; (c) strong specular reflection stripe; (d) weak reflection stripe
    Reliability evaluation results of light stripe centers. (a) Approximately ideal light stripe; (b) strong diffuse reflection stripe; (c) strong specular reflection stripe; (d) weak reflection stripe
    Time consumption comparison of extraction
    • Table 1. λ and Q(x) in energy model

      View table

      Table 1. λ and Q(x) in energy model

      ItemIdeal reflection stripeDiffuse reflection stripeSpecular reflection stripeWeak reflection stripe
      λλ=1λ>1λ>1λ<1
      Q(x)Q(x)≪λG0(x),Q(x)is negligibleQ(x)<λG0(x),Q(x)has effect on f(x)Q(x)<λG0(x),Q(x)has great effect on f(x)Q(x)≪λG0(x),Q(x)is negligibl
    • Table 2. Statistics of average confidence

      View table

      Table 2. Statistics of average confidence

      MethodAverage confidence of extracted centers Ca
      Approximately ideal light stripeStrong diffuse reflection stripeStrong specular reflection stripeWeak reflection stripe
      Method 11372.154903.023592.5189.08
      Method 21332.155041.374401192.15
      Method 31394.655550.823588.93271.15
      Method 41407.356521.384685275.13
    Tools

    Get Citation

    Copy Citation Text

    Taotao Li, Feng Yang, Shigeng Li, Yu He. Extraction Method of Line-Structured Light Stripe Center Based on Gauss-Lorenz Decomposition Peak Fitting[J]. Laser & Optoelectronics Progress, 2019, 56(7): 071201

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Sep. 11, 2018

    Accepted: Oct. 22, 2018

    Published Online: Jul. 30, 2019

    The Author Email: Taotao Li (ltaotao1988@126.com)