Chinese Optics, Volume. 17, Issue 2, 374(2024)

Design of terahertz wave imaging optical system with large aperture

Yi-qing CAO1,2、* and Zhi-juan SHEN1
Author Affiliations
  • 1School of Mechanical, Electrical & Information Engineering, Putian University, Putian 351100, China
  • 2Fujian Laser Precision Machining Engineering Technology Research Center, Putian 351100, China
  • show less
    Figures & Tables(12)
    Simplify structure and optical pass diagram using thin lens in optical system infrastructure
    Simplified structure and optical path diagram for initial structure of the optical system
    Optical structure and optical path diagram of the optical system after optimization design
    MTF curve diagram of the optical system after optimization design
    Spot diagram of the optical system after optimization design
    Relative illumination curve diagram of the optical system after optimization design
    F-Tan (Theta) distortion curve diagram of the optical system after optimization design
    Yield estimate curve
    • Table 1. Design specifications of the optical system

      View table
      View in Article

      Table 1. Design specifications of the optical system

      ParameterValue
      Wavelength band/μm30-35
      Effective focal length/mm70
      Full field of view angle/(°)8
      F-number1.4
      Pixel size/μm52×52
      Pixel240×320
    • Table 2. First-order optical parameter of the initial structure of the optical system (Unit: mm−1, unless otherwise stated)

      View table
      View in Article

      Table 2. First-order optical parameter of the initial structure of the optical system (Unit: mm−1, unless otherwise stated)

      $ \varPhi_{1} $$ \varPhi_{2} $$ \varPhi_{3} $$ \varPhi_{4} $$ d_{1} $$ d_{1} $$ d_{3} $
      −0.01570.0356−0.02010.02646 mm15.51 mm80 mm
    • Table 3. Sellmeier function fitting parameters of KRS-5 and CsBr materials

      View table
      View in Article

      Table 3. Sellmeier function fitting parameters of KRS-5 and CsBr materials

      Sellmeier fitting parametersMaterial
      KRS-5CsBr
      $ {K}_{1} $1.82939580.9533786
      $ L_{1} $2.25×10−28.20189243×10−3
      $ {K}_{2} $1.66755930.8303809
      $ L_{2} $6.25×10−22.79396908×10−2
      $ {K}_{3} $1.12104242.847172
      $ L_{3} $0.12251.41646892×104
      $ {K}_{4} $4.513366×10−2-
      $ L_{4} $0.2025-
      $ {K}_{5} $12.380234-
      $ L_{3} $2.70898681×104-
    • Table 4. Optical structure parameters of the optical system after optimization design

      View table
      View in Article

      Table 4. Optical structure parameters of the optical system after optimization design

      SurfaceTypeRadius/mmThickness/mmMaterial
      1Even Aspheric (STOP)−83.936.28CsBr
      2Even Aspheric46.660.70
      3Even Aspheric27.4514.98KRS-5
      4Even Aspheric185.487.65
      5Even Aspheric−27.0017.50CsBr
      6Standard32.643.25
      7Even Aspheric38.6117.50KRS-5
      8Standard316.4335.47
      Image planeStandardInfinite
    Tools

    Get Citation

    Copy Citation Text

    Yi-qing CAO, Zhi-juan SHEN. Design of terahertz wave imaging optical system with large aperture[J]. Chinese Optics, 2024, 17(2): 374