High Power Laser and Particle Beams, Volume. 34, Issue 11, 116001(2022)

Preliminary study on scatter quantification method for flash Multi-MeV radiography

Qinggang Jia1, Pengcheng Mao2, Wenyuan Wang1, Linghai Kong1, Bo Yang1, and Haibo Xu1
Author Affiliations
  • 1Institute of Applied Physics and Computational Mathematics, Beijing 100088, China
  • 2Graduate School of China Academy of Engineering Physics, Beijing 100094, China
  • show less
    Figures & Tables(11)
    Basic layout and improvement plan (framed) of flash radiography
    One-dimensional density distributions of FTO-like objects
    Primary and scatter X-ray distribution of FTO-U35 with inverted collimation
    Expected intensity distribution of FTO-U35 at the 2D array and downstream slit
    Expected intensity distribution of the array screen and the adjusted slit quasi-FFTO-U35 photography
    FTO-U30 camera slit straight through and scattering intensity distribution before and after collimation
    FTO-U40 camera slit straight through and scattering intensity distribution before and after collimation
    FTO-U45 photographic slit straight-through and scattering intensity distribution before and after collimation
    Schematic diagram of the visualized cross-section of the array collimator
    • Table 1. Calibration of R by FTO-U30 object to estimate the scattering value of other objects

      View table
      View in Article

      Table 1. Calibration of R by FTO-U30 object to estimate the scattering value of other objects

      object namevariation before and after slit collimation (measurement) simulated scatter value calculated scatter value scatter after collimation (simulation) Rrelative deviation/%
      FTO-U30(for calibration)0.02940.0640.00590.0975
      FTO-U400.0350.0550.0560.0975+1.8
      FTO-U450.0350.0550.0560.0975+1.8
    • Table 2. Calibration of R by FTO-U45 object to estimate the scattering value of other objects

      View table
      View in Article

      Table 2. Calibration of R by FTO-U45 object to estimate the scattering value of other objects

      object namevariation before and after slit collimation (measurement) simulated scatter value calculated scatter value scatter after collimation (simulation) Rrelative deviation/%
      FTO-U45(for calibration)0.03540.0550.00520.0945
      FTO-U300.02940.0620.0460.0945−25.6
      FTO-U350.0340.0600.0530.0945−11.7
    Tools

    Get Citation

    Copy Citation Text

    Qinggang Jia, Pengcheng Mao, Wenyuan Wang, Linghai Kong, Bo Yang, Haibo Xu. Preliminary study on scatter quantification method for flash Multi-MeV radiography[J]. High Power Laser and Particle Beams, 2022, 34(11): 116001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Nuclear Science and Engineering

    Received: Nov. 12, 2021

    Accepted: Jul. 7, 2022

    Published Online: Oct. 18, 2022

    The Author Email:

    DOI:10.11884/HPLPB202234.210488

    Topics