Acta Optica Sinica, Volume. 41, Issue 21, 2107001(2021)

Analysis and Optimization of Instantaneous Frequency Measurement System Based on Polarization Time Delay Interference

Wei Zhu, Jing Li*, Li Pei, Tigang Ning, Jingjing Zheng, and Jianshuai Wang
Author Affiliations
  • Institute of Lightwave Technology, Beijing Jiaotong University, Beijing 100044, China
  • show less
    Figures & Tables(10)
    Structural diagram of IFM system based on polarization delay interference
    Relationship between magnitude of Bessel function and m
    ACF curves under different time delays
    Relationship between maximum frequency and time delay
    Simulated ACF curve and estimated error curve. (a) simulated optical power curve and ACF curve; (b) comparison between theoretical instantaneous frequency and simulated instantaneous frequency; (c) error between theoretical instantaneous frequency and simulated instantaneous frequency
    Influence of wavelength drift on system. (a) ACF curves under different wavelength drifts; (b) error between theoretical instantaneous frequency and simulated instantaneous frequency
    Influence of radio frequency voltage on system. (a) ACF curves under different radio frequency voltages; (b) error between theoretical instantaneous frequency and simulated instantaneous frequency
    Influence of bias voltage drift on system. (a) ACF curves under different bias voltage drifts; (b) error between theoretical instantaneous frequency and simulated instantaneous frequency
    Influence of extinction ratio on system. (a) ACF curves under different extinction ratios; (b) error between theoretical instantaneous frequency and simulated instantaneous frequency
    Influence of polarization angle drift on system. (a) ACF curves under different polarization angle drifts; (b) error between theoretical instantaneous frequency and simulated instantaneous frequency
    Tools

    Get Citation

    Copy Citation Text

    Wei Zhu, Jing Li, Li Pei, Tigang Ning, Jingjing Zheng, Jianshuai Wang. Analysis and Optimization of Instantaneous Frequency Measurement System Based on Polarization Time Delay Interference[J]. Acta Optica Sinica, 2021, 41(21): 2107001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Fourier optics and signal processing

    Received: Mar. 4, 2021

    Accepted: May. 17, 2021

    Published Online: Nov. 17, 2021

    The Author Email: Li Jing (lijing@bjtu.edu.cn)

    DOI:10.3788/AOS202141.2107001

    Topics