Laser & Optoelectronics Progress, Volume. 59, Issue 7, 0722002(2022)

Three-Magnification Double-Telecentric Optical System and Effect of Field on Optical Design

Linghong Liu1, Yun Feng1、*, Liuhua Nong2, and Xuehui Tang2
Author Affiliations
  • 1Research and Development Department, Guilin Measuring & Cutting Tool Co., Ltd., Guilin , Guangxi 541004, China
  • 2Research and Development Department, Guilin URIT Medical Electronic Co., Ltd., Guilin , Guangxi 541004, China
  • show less
    Figures & Tables(17)
    Sketch map of double-telecentric system
    System initial structural diagram
    Outline drawing of optical system
    Light path diagram of the three-magnification double-telecentric system
    MTF plots. (a)-0.11×; (b)-0.44×; (c)-0.24×
    Spot diagrams. (a)-0.11×; (b)-0.44×; (c)-0.24×
    System distortion when magnification is -0.11. (a) Field curvature /distortion; (b) grid distortion
    System distortion when magnification is -0.44. (a) Field curvature /distortion; (b) grid distortion
    System distortion when magnification is -0.24. (a) Field curvature/distortion; (b) grid distortion
    • Table 1. Technical indexes of the telecentric optical system

      View table

      Table 1. Technical indexes of the telecentric optical system

      System parameterTechnical index
      Working distance /mm110
      F-number6
      Field of object /mm100, 25, 25
      Magnification-0.11,-0.24, -0.44
      Field of image /mm11,6, 11
      Distortion /%<0.1
      MTF at 145 lp/mm>0.3
      Telecentricity /(°)<0.1
    • Table 2. System telecentricity

      View table

      Table 2. System telecentricity

      MagnificationTelecentricity /(°)
      0H0.3H0.5H0.7H1H
      -0.11×0.01710.00220.01250.01720.0113
      -0.24×0.00380.00140.00230.00290.0034
      -0.44×0.00010.00170.00270.00350.0042
    • Table 3. The worst performance when magnification is -0.11

      View table

      Table 3. The worst performance when magnification is -0.11

      TypeSurfaceSurfaceValueCriterionChange
      TIRY1111-0.0125000000.28336434-0.07062743
      TIRX11110.0125000000.29291312-0.06107864
      TIRX1111-0.0125000000.29291312-0.06107864
      TIRY11110.0125000000.30447000-0.04952176
      TIRY1212-0.0125000000.31281091-0.04118085
      TSDY990.0125000000.31467464-0.03931712
    • Table 4. MTF and tolerance analysis when magnification is -0.11

      View table

      Table 4. MTF and tolerance analysis when magnification is -0.11

      Ratio>90%>80%>50%>20%>10%
      MTF at 135 lp/mm0.217236030.225490330.289382800.309410170.32025872
      Max distortion /%0.0980.0770.0680.0420.031
    • Table 5. The worst performance when magnification is -0.44

      View table

      Table 5. The worst performance when magnification is -0.44

      TypeSurfaceSurfaceValueCriterionChange
      TIRY1212-0.0125000000.31327321-0.02209004
      TIRY12120.0125000000.31327321-0.02209004
      TIRX1212-0.0125000000.31327321-0.02209004
      TIRX12120.0125000000.31327321-0.02209004
      TEDX1112-0.0125000000.31896806-0.01639519
      TEDX11120.0125000000.31896806-0.01639519
    • Table 6. MTF and tolerance analysis when magnification is -0.44

      View table

      Table 6. MTF and tolerance analysis when magnification is -0.44

      Ratio>90%>80%>50%>20%>10%
      MTF at 145 lp/mm0.252296330.272866510.295865360.315138170.31844695
      Max distortion /%0.0380.0320.0280.0220.020
    • Table 7. The worst performance when magnification is -0.24

      View table

      Table 7. The worst performance when magnification is -0.24

      TypeSurfaceSurfaceValueCriterionChange
      TEDX1011-0.025000000.34125771-0.06854529
      TEDX10110.025000000.34125771-0.06854529
      TEDY1011-0.025000000.34126254-0.06854047
      TEDY10110.025000000.34126254-0.06854047
      TIRX1111-0.025000000.35255514-0.05724787
      TIRX11110.025000000.35255514-0.05724787
    • Table 8. MTF and tolerance analysis when magnification is -0.24

      View table

      Table 8. MTF and tolerance analysis when magnification is -0.24

      Ratio>90%>80%>50%>20%>10%
      MTF at 135 lp/mm0.237430360.262375730.319072850.351480230.36730875
      Max distortion /%0.0510.0430.0320.0210.011
    Tools

    Get Citation

    Copy Citation Text

    Linghong Liu, Yun Feng, Liuhua Nong, Xuehui Tang. Three-Magnification Double-Telecentric Optical System and Effect of Field on Optical Design[J]. Laser & Optoelectronics Progress, 2022, 59(7): 0722002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Jul. 28, 2021

    Accepted: Aug. 26, 2021

    Published Online: Apr. 7, 2022

    The Author Email: Yun Feng (fengyun@sinoshan.com)

    DOI:10.3788/LOP202259.0722002