Acta Optica Sinica, Volume. 38, Issue 1, 0128004(2018)

Sensitivity of Intercalibration Uncertainty on Spectral Sampling of Space-Based Radiance Standard

Shenwei Chen1, Na Xu2,3、*, Tie Dai4, Xinyi Zhou1, Hao Lü1, and Yueming Cheng1
Author Affiliations
  • 1 School of Environmental Science and Engineering, Nanjing University of Information Science & Technology, Nanjing, Jiangsu 210044, China;
  • 2 National Satellite Meteorological Center, China Meteorological Administration, Beijing 100081, China
  • 3 Key Laboratory of Radiometric Calibration and Validation for Environmental Satellites, China Meteorological Administration, Beijing 100081, China
  • 4 State Key Laboratory of Numerical Modeling for Atmospheric Sciences and Geophysical Fluid Dynamics, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China
  • show less
    References(23)

    [2] Xu N, Wu R H, Hu X Q et al. Integrated method for on-obit wide dynamic vicarious calibration of FY-3C MERSI reflective solar bands[J]. Acta Optica Sinica, 35, 1228001(2015).

    [6] Trenberth K E, Anthes R A, Belward A et al. Challenges of a sustained climate observing system[M]. ∥Asrar G R, Hurrell J W. Climate science for serving society. Netherlands: Springer, 13-50(2013).

    [7] Trenberth K E, Fasullo J T. Tracking earth's energy[J]. Science, 328, 316-317(2010).

    [9] Han Q J, Liu L, Fu Q Y et al. Vicarious calibration of multiple sensors based on reanalysis data of pseudo-invariant site[J]. Acta Optica Sinica, 34, 1128002(2014).

    [12] Sandford S P, Young D F, Corliss J M et al. CLARREO: cornerstone of the climate observing system measuring decadal change through accurate emitted infrared and reflected solar spectra and radio occultation[C]. SPIE, 7826, 782611(2010).

    [13] Hao X P, Song J, Sun J P et al. Vacuum radiance temperature national standard facility for infrared remote sensors of Chinese Fengyun meteorological satellites[J]. Optics and Precision Engineering, 23, 1845-1851(2015).

    [15] Zhao W N. Research on transfer chain for SI-traceable absolute spectral radiance calibration on-orbit with high accuracy[D]. Beijing: University of Chinese Academy of Sciences(2016).

    [17] Gao D Y, Hu Y B, Liu Y et al. Photoelectric detection efficiency calibration of double channel self-calibration radiation reference source[J]. Acta Optica Sinica, 36, 1130001(2016).

    [18] Zou P, Zheng X B, Wu H Y et al. Research on calibration of radiance detector based on trap detector[J]. Acta Optica Sinica, 33, 0712002(2013).

    [19] Xu N, Hu X Q, Chen L. Evaluation and correction of atmosphere contamination on the measurement of the spectral response of FY-2 water vapor channels[J]. Spectroscopy and Spectral Analysis, 37, 2325-2330(2017).

    [23] Ding L. Flight model (Z01-2) development review of FY-3A medium resolution spectral imager (MERSI)[R]. Shanghai: Shanghai Institute of Technical Physics of the Chinese Academy of Sciences(2005).

    Tools

    Get Citation

    Copy Citation Text

    Shenwei Chen, Na Xu, Tie Dai, Xinyi Zhou, Hao Lü, Yueming Cheng. Sensitivity of Intercalibration Uncertainty on Spectral Sampling of Space-Based Radiance Standard[J]. Acta Optica Sinica, 2018, 38(1): 0128004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Remote Sensing and Sensors

    Received: Jun. 26, 2017

    Accepted: --

    Published Online: Aug. 31, 2018

    The Author Email: Xu Na (xuna@cma.gov.cn)

    DOI:10.3788/AOS201838.0128004

    Topics