Chinese Optics Letters, Volume. 14, Issue 12, 121201(2016)

Autonomous vicarious calibration based on automated test-site radiometer

刚刚 邱1,2, 新 李1、*, 小兵 郑1、**, 静 闫1, and 彦港 孙3
Author Affiliations
  • 1Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China
  • 2University of Sciences and Technology of China, Hefei 230031, China
  • 3Shanghai Maritime University, Shanghai 201306, China
  • show less
    References(26)

    [2] H. N. Gross, C. J. Bruegge, M. C. Helmlinger. AIAA SPACE 2007 Conference & Exposition(2007).

    [5] K. Holekamp. JACIE Civil Commercial Imagery Evaluation Workshop(2006).

    [7] J. S. Czapla-Myers. Automated Ground-Based Methodology in Support of Vicarious Calibration(2006).

    [8] X. Li, X. B. Zheng, Y. P. Yin. J. Atmos. Environ. Opt., 9, 1(2014).

    [9] S. F. Biggar. In-Flight Methods for Satellite Sensor Absolute Radiometric Calibration(1990).

    [10] H. Gong, G. L. Tian, T. Yu. J. Beijing Jiaotong Univ., 34, 1(2010).

    [12] Y. P. Yin. Development of Automated Site Radiometer(2015).

    [14] K. Li, Z. Li, D. Li, W. Li, L. Blarel, P. Goloub, T. Benjamin, H. Xu, Y. Xie, W. Hou, L. Li, X. Chen. Chin. Opt. Lett., 13, 041001(2015).

    [15] M. Xia, J. Li, Z. Li, D. Gao, W. Pang, D. Li, X. Zheng. Chin. Opt. Lett., 12, 121201(2014).

    [16] L. Bian, B. S. Li, D. H. Li. Mod. Sci. Instrum., 6, 12(2013).

    [17] L. Li, J. Y. Yu, C. Tang, X. Tang. Environ. Sci. Manage., 37, 2(2012).

    [18] Y. P. Yin, X. Li, X. B. Zheng. J. Atmos. Environ. Opt., 11, 1(2016).

    [19] X. Li, Y. P. Yin, X. B. Zheng. Proc. SPIE, 2964, 29640(2015).

    [20] J. N. Guo, X. J. Min, Q. Y. Fu. J. Remote Sens., 10, 5(2006).

    [21] K. Thome, J. Czapla-Myers, S. Bihhar. Proc. SPIE, 5151, 786(2003).

    [22] W. W. Pang, X. B. Zheng, J. H. Lu, J. J. Li. J. Atmos. Environ. Opt., 10, 6(2015).

    [25] S. F. Biggar, P. N. Slater, D. I. Gellman. Remote Sens. Environ., 48, 245(1994).

    [26] S. Fan, M. Liu, H. Shen. Chin. Opt. Lett., 12, 051201(2014).

    CLP Journals

    [1] Wei Wei, Shuai Song, Yangang Sun, Ganggang Qiu, Xin Li, Xiaobing Zheng, "Development and application of automated vicarious calibration system," Chin. Opt. Lett. 15, 100101 (2017)

    Cited By
    Tools

    Get Citation

    Copy Citation Text

    刚刚 邱, 新 李, 小兵 郑, 静 闫, 彦港 孙, "Autonomous vicarious calibration based on automated test-site radiometer," Chin. Opt. Lett. 14, 121201 (2016)

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, measurement, and metrology

    Received: Aug. 12, 2016

    Accepted: Oct. 21, 2016

    Published Online: Aug. 2, 2018

    The Author Email: 新 李 (xli@aiofm.ac.cn), 小兵 郑 (xbzheng@aiofm.ac.cn)

    DOI:10.3788/COL201614.121201

    Topics