Acta Optica Sinica, Volume. 32, Issue 7, 717001(2012)
Design and Property of Depth-Selective Fiber-Optical Probes Applied in Diffuse Reflection Measurement
[1] [1] G. Marquez, L. H. Wang. White light oblique incidence reflectometer for measuring absorption and reduced scattering spectra of tissue like turbid media [J]. Opt. Express, 1997, 1(13): 454~460
[2] [2] K. Sokolov, R. Drezek, K. Gossage et al.. reflection spectroscopy with polarized light: is it sensitive to cellular and nuclear morphology [J]. Opt. Express, 1999, 5(13): 302~317
[4] [4] J. R. Mourant, I. Bigio, J. Boyer et al.. Spectroscopic diagnosis of bladder cancer with elastic light scattering [J]. Lasers Surgery and Medicine, 1995, 17(4): 350~357
[5] [5] A. Amelink, H. J. C. M. Sterenborg, M. P. L. Bard et al.. In vivo measurement of the local optical properties of tissue by use of differential path-length spectroscopy [J]. Opt. Lett., 2004, 29(10): 1087~1089
[6] [6] A. N. Bashkatov, E. A. Genina, V. V. Tuchin. Optical properties of skin, subcutaneous and muscle tissues: a review [J]. J. Innovative Optical Health Science, 2011, 4(1): 9~38
[7] [7] Y. Lee. Skin thickness of Korean adults [J]. Surgical and Radiologic Anatomy, 2002, 24(3-4): 183~189
[8] [8] J. R. Mourant, I. Bigio, D. Jack et al.. Measuring absorption coefficients in small volumes of highly scattering media: source-detector separations for which path lengths do not depend on scattering properties [J]. Appl. Opt., 1997, 36(22): 5655~5661
[9] [9] Myakov, L. Nieman, L. Wicky, U. Utzinger et al.. Fiber optic probe for polarized reflection spectroscopy in vivo: design and performance [J]. J. Biomed. Opt., 2002, 7(3): 388~397
[10] [10] C. Zhu, Q. Liu, N. Ramanujam. Effect of fiber optic probe geometry on depth-resolved fluorescence measurements from epithelial tissues: a Monte Carlo simulation [J]. J. Biomed. Opt., 2003, 8(2): 237~247
[11] [11] M. Skala, G. Palmer, C. Zhu et al.. Investigation of fiber optic probe designs for optical spectroscopic diagnosis of epithelial precancers [J]. Lasers in Surgery and Medicine, 2004, 34(1): 25~38
[12] [12] T. J. Pfefer, L. Matchette, R. Drezek. Influence of illumination collection geometry on fluorescence spectroscopy in multi-layered tissue [J]. Med. Biol. Engng. Comput., 2004, 42(5): 669~673
[13] [13] A. M. J. Wang, J. E. Bender, J. Pfefer et al.. Depth-sensitive reflection measurements using obliquely oriented fiber probes [J]. J. Biomed. Opt., 2005, 10(4): 044017
[15] [15] L. H. Wang, S. L. Jacques, L.Q. Zhang. MCML-Monte Carlo modeling of light transport in multi-layered tissues [J]. Comput. Methods Programs Biomed., 1995, 47(2): 131~146
[17] [17] Wang Anle, Li Ting, Deng Yong et al.. Influence of real forearm structure on light transport based on MCVMW[J]. Acta Optica Sinica, 2011, 31(3): 0317002
Get Citation
Copy Citation Text
Li Chenxi, Zhao Huijuan, Zheng Jiaxiang, Xu Kexin. Design and Property of Depth-Selective Fiber-Optical Probes Applied in Diffuse Reflection Measurement[J]. Acta Optica Sinica, 2012, 32(7): 717001
Category: Medical optics and biotechnology
Received: Jan. 19, 2012
Accepted: --
Published Online: May. 24, 2012
The Author Email: Chenxi Li (lichenxi@tju.edu.cn)