Acta Optica Sinica, Volume. 32, Issue 7, 717001(2012)

Design and Property of Depth-Selective Fiber-Optical Probes Applied in Diffuse Reflection Measurement

Li Chenxi1,2、*, Zhao Huijuan2, Zheng Jiaxiang1, and Xu Kexin1,2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(17)

    [1] [1] G. Marquez, L. H. Wang. White light oblique incidence reflectometer for measuring absorption and reduced scattering spectra of tissue like turbid media [J]. Opt. Express, 1997, 1(13): 454~460

    [2] [2] K. Sokolov, R. Drezek, K. Gossage et al.. reflection spectroscopy with polarized light: is it sensitive to cellular and nuclear morphology [J]. Opt. Express, 1999, 5(13): 302~317

    [4] [4] J. R. Mourant, I. Bigio, J. Boyer et al.. Spectroscopic diagnosis of bladder cancer with elastic light scattering [J]. Lasers Surgery and Medicine, 1995, 17(4): 350~357

    [5] [5] A. Amelink, H. J. C. M. Sterenborg, M. P. L. Bard et al.. In vivo measurement of the local optical properties of tissue by use of differential path-length spectroscopy [J]. Opt. Lett., 2004, 29(10): 1087~1089

    [6] [6] A. N. Bashkatov, E. A. Genina, V. V. Tuchin. Optical properties of skin, subcutaneous and muscle tissues: a review [J]. J. Innovative Optical Health Science, 2011, 4(1): 9~38

    [7] [7] Y. Lee. Skin thickness of Korean adults [J]. Surgical and Radiologic Anatomy, 2002, 24(3-4): 183~189

    [8] [8] J. R. Mourant, I. Bigio, D. Jack et al.. Measuring absorption coefficients in small volumes of highly scattering media: source-detector separations for which path lengths do not depend on scattering properties [J]. Appl. Opt., 1997, 36(22): 5655~5661

    [9] [9] Myakov, L. Nieman, L. Wicky, U. Utzinger et al.. Fiber optic probe for polarized reflection spectroscopy in vivo: design and performance [J]. J. Biomed. Opt., 2002, 7(3): 388~397

    [10] [10] C. Zhu, Q. Liu, N. Ramanujam. Effect of fiber optic probe geometry on depth-resolved fluorescence measurements from epithelial tissues: a Monte Carlo simulation [J]. J. Biomed. Opt., 2003, 8(2): 237~247

    [11] [11] M. Skala, G. Palmer, C. Zhu et al.. Investigation of fiber optic probe designs for optical spectroscopic diagnosis of epithelial precancers [J]. Lasers in Surgery and Medicine, 2004, 34(1): 25~38

    [12] [12] T. J. Pfefer, L. Matchette, R. Drezek. Influence of illumination collection geometry on fluorescence spectroscopy in multi-layered tissue [J]. Med. Biol. Engng. Comput., 2004, 42(5): 669~673

    [13] [13] A. M. J. Wang, J. E. Bender, J. Pfefer et al.. Depth-sensitive reflection measurements using obliquely oriented fiber probes [J]. J. Biomed. Opt., 2005, 10(4): 044017

    [15] [15] L. H. Wang, S. L. Jacques, L.Q. Zhang. MCML-Monte Carlo modeling of light transport in multi-layered tissues [J]. Comput. Methods Programs Biomed., 1995, 47(2): 131~146

    [17] [17] Wang Anle, Li Ting, Deng Yong et al.. Influence of real forearm structure on light transport based on MCVMW[J]. Acta Optica Sinica, 2011, 31(3): 0317002

    CLP Journals

    [1] Li Fei, Zhang Yuanzhi, Wang Yikun, Zhu Ling, Liu Yong, Wang An. Determination of Optical Parameters of Turbid Media Based on Real Coded Genetic Algorithm[J]. Acta Optica Sinica, 2013, 33(12): 1217001

    [2] Wu Chunyang, Lu Qipeng, Ding Haiquan, Gao Hongzhi. Noninvasive Blood Glucose Sensing with Near-Infrared Spectroscopy Based on Interstitial Fluid[J]. Acta Optica Sinica, 2013, 33(11): 1117001

    [3] Wu Chunyang, Lu Qipeng, Ding Haiquan, Gao Hongzhi. Noninvasive Blood Glucose Sensing with Near-Infrared Spectroscopy Based on Interstitial Fluid[J]. Acta Optica Sinica, 2013, 33(11): 1117001

    [4] Hou Huayi, Fang Zhaohui, Zhang Yuanzhi, Dong Meili, Zhu Ling, Wang Yikun, Ye Xingshun, Sang Yaoshuo, Liu Yong. Simulation and in vivo Experimental Study on Noninvasive Spectral Detection of Skin Cholesterol[J]. Chinese Journal of Lasers, 2016, 43(9): 907001

    [5] Qu Ruoyuan, Hou Liping, Feng Xiang, Wang Zhiji, Wu Kan, Zou Weiwen, Chen Jianping. Constant Pressure Fiber Attenuated Total Reflection Probe Used in Infrared Spectrum Analysis[J]. Acta Optica Sinica, 2017, 37(5): 506003

    Tools

    Get Citation

    Copy Citation Text

    Li Chenxi, Zhao Huijuan, Zheng Jiaxiang, Xu Kexin. Design and Property of Depth-Selective Fiber-Optical Probes Applied in Diffuse Reflection Measurement[J]. Acta Optica Sinica, 2012, 32(7): 717001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Medical optics and biotechnology

    Received: Jan. 19, 2012

    Accepted: --

    Published Online: May. 24, 2012

    The Author Email: Chenxi Li (lichenxi@tju.edu.cn)

    DOI:10.3788/aos201232.0717001

    Topics