Acta Optica Sinica, Volume. 44, Issue 16, 1611004(2024)
Single-Pixel High-Resolution Imaging System Based on PnP-ADMM SOC Platform
Fig. 1. Flowchart of PnP-ADMM rapid reconstruction algorithm. (a) Flow chart; (b) PnP-ADMM algorithm
Fig. 2. Comparison of numerical simulation reconstruction results of different algorithms. (a) Original images; (b) WQR-OMP; (c) TVAL3; (d) PnP-ADMM (Prox); (e) PnP-ADMM (Shrinkage); (f) PnP-ADMM (TV)
Fig. 3. Comparison of reconstruction performance for different algorithms. (a) PSNR; (b) SSIM; (c) reconstruction time
Fig. 4. Reconstruction results of PnP-ADMM algorithm under different sampling rates. (a) Lena; (b) Peppers; (c) LOGO; (d) House; (e) USAF-1951 resolution test chart
Fig. 5. Comparison of reconstruction performance of PnP-ADMM algorithm under different sampling rates. PSNR of (a) Prox, (b) Shrinkage, and (c) TV; SSIM of (d) Prox, (e) Shrinkage, and (f) TV
Fig. 6. Compressive sampling hardware architecture of PnP-ADMM reconstruction algorithm
Fig. 7. SPI system based on PnP-ADMM SOC (imaging distance is 300 cm). (a) Single-pixel detector and collimating lens; (b) DMD and imaging reconstruction FPGA
Fig. 8. Experimental reconstruction results of PnP-ADMM SOC single-pixel imaging system under different sampling rates. (a) LOGO; (b) USAF-1951 resolution test chart; (c) checkerboard
Fig. 9. Experimental reconstruction results of PnP-ADMM SOC single-pixel imaging system under different imaging distances. (a) LOGO; (b) USAF-1951 resolution test chart; (c) checkerboard
|
|
Get Citation
Copy Citation Text
Miao Li, Lingqiang Zhang, Xi Wang, Chenyan Wang, Chaorui Chen, Zhaohui Guo, Xueyin Zhao. Single-Pixel High-Resolution Imaging System Based on PnP-ADMM SOC Platform[J]. Acta Optica Sinica, 2024, 44(16): 1611004
Category: Imaging Systems
Received: Apr. 3, 2024
Accepted: May. 6, 2024
Published Online: Aug. 5, 2024
The Author Email: Wang Xi (xiwang@cqupt.edu.cn)
CSTR:32393.14.AOS240802