NUCLEAR TECHNIQUES, Volume. 48, Issue 7, 070032(2025)

Effects of heat exchange element thimble leakage on the thermal transfer characteristics of emergency water-cooled fuel salt drain system of molten salt reactor

Liangjie SUN1,2, Rongjian LIANG1, Wentao JIANG1,2, Chaoqun WANG1,2, Qun YANG1,2、*, Zhaozhong HE1, Yang ZOU1,2, and Hongjie XU1,2
Author Affiliations
  • 1Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    Figures & Tables(18)
    Diagram of the heat removal system of the drain tank
    Schematic illustration of the heat exchanger element (color online)
    Decay heat power of molten salt within the first hour after the completion of the fuel drain process
    Structural diagram of the heat exchanger element model (color online) (a) Low section, (b) Middle section
    Steady-state temperature distribution of the heat exchanger element (color online)
    Distribution of steady-state temperature at a height of 10 mm
    Volume fraction contour of molten salt in the annual gas space (color online)
    Mass flow rate vs. time (color online)
    Vapor volume fraction contour within heat exchanger element (color online)(a) Before leak occurring, (b) After leak occurring
    Molten salt mass flow vs. time at leak location
    Volume fraction distribution of frozen molten salt in the annular gas space
    Temperature distribution when leak occurring (color online)
    Power and mass flow rate vs. the height of leak location (color online)
    Power and mass flow rate vs. pressure difference at a leakage size of 4 mm (color online)
    Variations of power and mass flow rate with leak size in the range of 2~5 mm (color online)
    Mass flow rate vs. time at a leakage size of 7 mm (color online)
    • Table 1. Sizes of the heat exchanger element

      View table
      View in Article

      Table 1. Sizes of the heat exchanger element

      结构Structures尺寸Dimensions
      下降管Downcomer12.70 mm,2.096 m in length
      内层套管Bayonet tube25.40 mm,2.149 m in length
      外层套管Thimble38.10 mm,1.968 m in length
      加热段长度Heating length1.7 m
    • Table 2. Thermophysical parameters

      View table
      View in Article

      Table 2. Thermophysical parameters

      物性参数

      Physical parameters

      冷却水

      Water coolant

      哈氏合金

      INOR-8

      熔盐

      Salt

      热导率Thermal conductivity / W·(m·K)-10.620.31.4
      密度Density / kg·m-3998.28 8602 757.9-0.464T
      比热容Heat capacity / J·(kg·K)-14 1825862 386
      黏度Viscosity / Pa·s0.001 0031.43-4.310×10-3T+4.358×10-6T2-1.487×10-9T3
    Tools

    Get Citation

    Copy Citation Text

    Liangjie SUN, Rongjian LIANG, Wentao JIANG, Chaoqun WANG, Qun YANG, Zhaozhong HE, Yang ZOU, Hongjie XU. Effects of heat exchange element thimble leakage on the thermal transfer characteristics of emergency water-cooled fuel salt drain system of molten salt reactor[J]. NUCLEAR TECHNIQUES, 2025, 48(7): 070032

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Special Issue on The First Academic Annual Conference of the Research Reactor and Innovative Reactor Association of Chinese Nuclear Society and Advanced Nuclear Power System Reactor Engineering

    Received: Sep. 9, 2024

    Accepted: --

    Published Online: Sep. 15, 2025

    The Author Email: Qun YANG (YANGQun)

    DOI:10.11889/j.0253-3219.2025.hjs.48.240271