Acta Optica Sinica, Volume. 43, Issue 19, 1906001(2023)

Cascaded Double-Cavity Temperature Sensor Sensitized by Polydimethylsiloxane

Yuqiang Yang1,2,4, Jiale Gao1,4, Xiaoguang Mu3、*, Ji Wang2,4、**, Wenhu Yang1,4, Yitong Li2,4, and Chuhong Wang4
Author Affiliations
  • 1Shenzhen Institute of Guangdong Ocean University, Shenzhen 518120, Guangdong , China
  • 2Guangdong Provincial Engineering Research Center for Ship Intelligence and Safety, Guangdong Ocean University, Zhanjiang 524088, Guangdong , China
  • 3College of Mechanical Engineering, Guangdong Ocean University, Zhanjiang 524088, Guangdong , China
  • 4Research Center of Guangdong Smart Oceans Sensor Networks and Equipment Engineering, Guangdong Ocean University, Zhanjiang 524088, Guangdong , China
  • show less
    Figures & Tables(10)
    Schematic diagram of proposed sensor
    Simulation results of interference spectra of PDMS cavity and air cavity before and after cascading. (a) Interference spectrum of single PDMS cavity; (b) interference spectrum of single air cavity; (c) interference spectrum of cascaded two cavities
    Interference spectrum shift with temperature increasing from 40 ℃ to 41 ℃. (a) Single PDMS cavity; (b) single air cavity; (c) cascaded two cavities
    Micrograph of PDMS cavity. (a) Micrograph of PDMS cavity before packaging; (b) micrograph of PDMS cavity and air cavity after packaging
    Interference spectra of PDMS cavity under different temperatures and peak wavelength of PDMS cavity versus temperature. (a) Interference spectra of PDMS cavity; (b) curve of peak wavelength of interference spectra of PDMS cavity versus temperature
    Temperature sensor device diagram
    Interference spectrum of cascaded two cavities
    Interference spectral envelopes under different temperatures
    Peak wavelength shift of interference spectral envelope with temperature rising and falling
    • Table 1. Comparison of temperature sensitivities of different fiber sensors

      View table

      Table 1. Comparison of temperature sensitivities of different fiber sensors

      Sensor configurationRange /℃Sensitivity /(nm·℃-1Size /μmReference
      Parallel air and PDMS FPIs46-5017.758~14022
      Cascaded air and PDMS FPIs40-563.980~60023
      Two parallel PDMS FPIs50-60-14.600~20024
      Parallel two SIs31-3578.984~210000026
      Two cascaded all-fiber FPIs250-10501.109~800027
      Using an air-cavity with PDMS at both ends40-42-21.100~1000This work
    Tools

    Get Citation

    Copy Citation Text

    Yuqiang Yang, Jiale Gao, Xiaoguang Mu, Ji Wang, Wenhu Yang, Yitong Li, Chuhong Wang. Cascaded Double-Cavity Temperature Sensor Sensitized by Polydimethylsiloxane[J]. Acta Optica Sinica, 2023, 43(19): 1906001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Fiber Optics and Optical Communications

    Received: Jan. 4, 2023

    Accepted: Apr. 13, 2023

    Published Online: Sep. 28, 2023

    The Author Email: Xiaoguang Mu (xd_gdou@sina.com), Ji Wang (13902576499@163.com)

    DOI:10.3788/AOS230442

    Topics