Journal of Radiation Research and Radiation Processing, Volume. 40, Issue 5, 050601(2022)

Safety assessment of electromagnetic exposure of walk-through metal detectors operating at 6.48 kHz

Weijiang BAI and Mai LU*
Author Affiliations
  • Key Laboratory of Opto-Electronic Technology and Intelligent Control, Ministry of Education, Lanzhou Jiaotong University, Lanzhou 730070, China
  • show less
    References(23)

    [1] Misakian M, Casamento J P, Laug B. Development of emulator for walk-through metal detectors[J]. IEEE Transactions on Electromagnetic Compatibility, 44, 486-489(2002).

    [2] Wu D, Qiang R, Chen J et al. Possible overexposure of pregnant women to emissions from a walk through metal detector[J]. Physics in Medicine & Biology, 52, 5735-5748(2007).

    [3] Im C H, Jung H K. Numerical emulator for walk-through metal detectors using 3-D indirect boundary integral equation method[J]. IEEE Transactions on Instrumentation & Measurement, 54, 1166-1170(2005).

    [4] Orcutt N, Gandhi O P. A 3-D impedance method to calculate power deposition in biological bodies subjected to time varying magnetic fields[J]. IEEE transactions on bio-medical engineering, 35, 577(1988).

    [5] Nelson C, Chaudhary V, Edman J et al. Walk-through metal detectors for stadium security[C], 1-6(2016).

    [6] Kato M. Electromagnetics in Biology[J]. Springer Berlin, 30, 149-150(2010).

    [7] SONG Tao, HUO Xiaolin, WU Shizeng[M]. Bioelectromagnetic properties and their applications, 1-6(2008).

    [8] Chen X L, Benkler S, Li C H et al. Low frequency electromagnetic field exposure study with posable human body model[C], 2-5(2010).

    [9] Poljak D, Cvetkovic M, Dodig H et al. Electromagnetic-thermal analysis for human exposure to high frequency (HF) radiation[J]. International Journal of Design & Nature and Ecodynamics, 12, 55-67(2017).

    [10] ZHOU Jingcheng, LIN Yanyun, CHEN Keliang et al. Effects of radiation-frequency electromagnetic radiation on cholinergic neuronal markers of SD rat brain[J]. Journal of Radiation Research and Radiation Processing, 35, 010202(2017).

    [11] QU Min, BI Zhuoyue, TANG Yumeng et al. Application of bio-electromagnetic technique and its related health risk assessment strategy[J]. High Voltage Engineering, 41, 2625-2634(2015).

    [12] Gabriel C, Gabriel S, Corthout E. The dielectric properties of biological tissues: I. Literature survey[J]. Physics in Medicine & Biology, 41, 2231-49(1996).

    [13] Gabriel S, Lau R W, Gabriel C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz[J]. Physics in Medicine & Biology, 41, 2251-2269(1996).

    [14] Gabriel S, Lau R W, Gabriel C. The dielectric properties of biological tissues: III. Parametric models for the dielectric spec-trum of tissues[J]. Physics in Medicine and Biology, 41, 2271-2293(1996).

    [15] Korobsova V, Morozov Y, Stolorov M. Influence of the electric field in 500 and 750 kV switchyards on maintenance staff and means for its protection[C], 23-26(1972).

    [16] BAO Jiali. Health effects of extremely low frequency electromagnetic fields[J]. High Voltage Engineering, 41, 2550-2561(2015).

    [17] WANG Qin, SU Haifeng, BAO Jiali et al. Primary reaction for the environmental electric and magnetic fields exposure around High Voltage Transmission line on health effects[J]. High Voltage Engineering, 39, 193-200(2013).

    [18] Lu M, Ueno S. Comparison of the induced fields using different coil configurations during deep transcranial magnetic stimulation[J]. PLoS One, 12, e0178422(2017).

    [19] Lu M, Ueno S. Computational study toward deep transcranial magnetic stimulation using coaxial circular coils[J]. IEEE Transactions on Biomedical Engineering, 62, 2911-2919(2015).

    [20] CHEN Dengpeng, LU Mai. Exposure characteristics of 5G mobile phone antenna and its temperature field distribution in the human head[J]. Journal of Radiation Research and Radiation Processing, 39, 030601(2021).

    [21] DU Qingzhong, LU Mai. Safety assessment of electromagnetic exposure of quadruple-circuit AC transmission line with 1 000 kV/500 kV dual voltage on the same tower[J]. Journal of Radiation Research and Radiation Processing, 38, 020602(2020).

    [22] Editors G Z, Repacholi M, Mckinlay A. International commission on non-ionizing radiation protection[J]. Progress in Biophysics and Molecular Biology, 92, 1-3(2006).

    [27] HUANG Rui, ZENG Guoqiang, LUO Qun et al. Design of a weak signal processing circuit for metal security gates[J]. Measurement and Control Technology, 33, 4(2014).

    Tools

    Get Citation

    Copy Citation Text

    Weijiang BAI, Mai LU. Safety assessment of electromagnetic exposure of walk-through metal detectors operating at 6.48 kHz[J]. Journal of Radiation Research and Radiation Processing, 2022, 40(5): 050601

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Apr. 14, 2022

    Accepted: Jun. 21, 2022

    Published Online: Nov. 3, 2022

    The Author Email: Mai LU (mai.lu@126.com)

    DOI:10.11889/j.1000-3436.2022-0041

    Topics