Acta Optica Sinica, Volume. 40, Issue 9, 0930001(2020)

Rapid Detection of Quinolones in Water Based on Fluorescence Spectrometry and BLLS/RBL

Xingtao Zhao, Xiange Che, Shutao Wang*, Shiyu Liu, and Yuanyuan Yuan
Author Affiliations
  • Heibei Provincial Key Laboratory of Measurement Technology and Instrument, School of Electrical Engineering, Yanshan University, Qinhuangdao, Hebei 066004, China
  • show less
    Figures & Tables(6)
    Contour maps of sample T1 of mixed solution. (a) Before denoising; (b) after denoising
    Contour maps of samples C11, C12 and C13. (a) LVFX; (b) ENR; (c) FLU
    Determination of sample group score by core consistency diagnosis
    Actual and resolution spectra of BLLS/RBL. (a) Excitation spectra; (b) emission spectra
    • Table 1. Concentration of calibration and prediction samplesμg·L-1

      View table

      Table 1. Concentration of calibration and prediction samplesμg·L-1

      SampleFLUENRLVFXSampleFLUENRLVFX
      C120.002.002.00C11100.000.000.00
      C240.003.005.00C120.007.000.00
      C340.005.002.00C130.000.005.00
      C440.006.002.00T120.002.001.00
      C550.004.002.00T240.004.004.00
      C660.002.005.00T340.005.003.00
      C760.005.002.00T460.004.003.00
      C880.002.004.00T560.003.004.00
      C980.004.002.00T680.003.003.00
      C10100.003.002.00T7100.002.003.00
    • Table 2. Concentration prediction results

      View table

      Table 2. Concentration prediction results

      ParameterSampleBLLS/RBLPARAFAC
      FLUENRLVFXFLUENRLVFX
      Predictive concentration /(μg·L-1)[Recovery /%]T122.21[111.05]2.32[116.0]0.99[99.00]22.44[112.22]2.38[119.00]1.07[107.00]
      T235.25[88.13]3.51[87.75]4.42[110.50]33.94[84.85]4.52[113.00]4.69[117.25]
      T335.38[88.45]4.73[94.60]3.33[111.00]34.48[86.20]5.44[108.80]3.46[115.33]
      T467.35[112.25]4.22[105.50]3.27[109.00]65.72[109.53]4.36[109.00]2.57[85.67]
      T555.48[92.47]2.68[89.33]3.88[97.00]50.04[83.40]2.59[86.33]4.58[114.50]
      T677.22[96.52]3.36[112.00]2.76[92.00]76.46[95.58]3.41[113.67]2.47[82.33]
      T7100.32[100.32]1.77[88.50]2.80[93.33]102.39[102.39]1.68[84.00]2.79[93.00]
      AR /%98.4699.10101.6996.31104.83102.15
      RMSE /(μg·L-1)4.330.330.265.650.410.47
      SEN /1032.8355511428
      LOD /(μg·L-1)0.720.060.031.600.120.06
    Tools

    Get Citation

    Copy Citation Text

    Xingtao Zhao, Xiange Che, Shutao Wang, Shiyu Liu, Yuanyuan Yuan. Rapid Detection of Quinolones in Water Based on Fluorescence Spectrometry and BLLS/RBL[J]. Acta Optica Sinica, 2020, 40(9): 0930001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Spectroscopy

    Received: Nov. 26, 2019

    Accepted: Jan. 14, 2020

    Published Online: May. 6, 2020

    The Author Email: Shutao Wang (wangshutao@ysu.edu.cn)

    DOI:10.3788/AOS202040.0930001

    Topics