High Power Laser Science and Engineering, Volume. 12, Issue 3, 03000e23(2024)

Compact mid-infrared dual-comb spectrometer over 3–4 μm via intra-pulse difference frequency generation in LiNbO3 waveguides

Lian Zhou1, Haipeng Lou1, Zejiang Deng1, Xiong Qin1, Jiayi Pan1, Yuanfeng Di1, Chenglin Gu1, Daping Luo1、*, and Wenxue Li1,2、*
Author Affiliations
  • 1State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai, China
  • 2Joint Research Center of Light Manipulation Science and Photonic Integrated Chip of East China Normal University and Shandong Normal University, East China Normal University, Shanghai, China
  • show less
    Figures & Tables(6)
    Schematic of the MIR comb generation. The lens after the waveguide is to make the schematic easier to understand. In the actual system, we use an off-axis parabolic mirror to collimate the MIR light instead of the lens. LD, laser diode; EDF, Er-doped fiber; WDM, wavelength division multiplexer; Col, collimator; EDFA, Er-doped fiber amplifier; λ/2, half-wave plate; HNLF, highly nonlinear fiber; PPLN WG, periodically poled lithium niobate waveguide; and LPF, long-pass filter. Moreover, we also recorded the images of the PPLN WG using a phone camera (inset (a)) and a charge-coupled device (CCD) camera (inset (b)).
    (a) Autocorrelation trace and (b) measured spectrum of the compressor output.
    (a) Spectral profile of SCG. The spectral region is separately measured using a Yokogawa AQ6370 (900–1700 nm) and a Bristol 771B (1700–2400 nm). (b) Spectral profile of the MIR comb. (c) RIN of MIR light.
    (a) Schematic of the MIR dual-comb system. The recorded interferograms at different time scales of (b) 150 ms and (c) 0.02 ms. CW, continuous-wave laser; BPD, balanced photodetector; DAQ, data acquisition.
    Mode-resolved MIR dual-comb spectra at different wavelength scales of (a) 1.4 μm, (b) 0.002 μm and (c) 0.0002 μm.
    (a) Absorption lines of methane in the 3537–3547 nm region. (b) Zoom-in absorption line of methane at 3541.1–3541.3 nm. (c)–(e) Comparison results of the extracted gas absorption lines (blue dot) and the theoretical profiles from the HITRAN database (red line).
    Tools

    Get Citation

    Copy Citation Text

    Lian Zhou, Haipeng Lou, Zejiang Deng, Xiong Qin, Jiayi Pan, Yuanfeng Di, Chenglin Gu, Daping Luo, Wenxue Li. Compact mid-infrared dual-comb spectrometer over 3–4 μm via intra-pulse difference frequency generation in LiNbO3 waveguides[J]. High Power Laser Science and Engineering, 2024, 12(3): 03000e23

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Nov. 14, 2023

    Accepted: Jan. 15, 2024

    Published Online: May. 13, 2024

    The Author Email: Daping Luo (dpluo@lps.ecnu.edu.cn), Wenxue Li (wxli@phy.ecnu.edu.cn)

    DOI:10.1017/hpl.2024.2

    CSTR:32185.14.hpl.2024.2

    Topics