Laser & Optoelectronics Progress, Volume. 61, Issue 6, 0618017(2024)

New Light in Microscopic Exploration: Portable Photoacoustic Microscopy (Invited)

Mingli Sun, Chiye Li, Ruimin Chen, and Junhui Shi*
Author Affiliations
  • Research Center for Humanoid Sensing, Zhejiang Lab, Hangzhou 311121, Zhejiang, China
  • show less
    Figures & Tables(9)
    Schematic of photoacoustic imaging[30]
    Basic implementation of PAM. (a) Transmissive OR-PAM[30,35]; (b) reflective OR-PAM[30,36]; (c) AR-PAM based on dark field illumination[30,39]
    Structural and functional imaging of PAM. (a) Multi-parameter measurement of the mouse brain[57]; (b) multi-parameter measurement of the mouse ear[41]; (c) imaging of an in vitro melanoma cell and a red blood cell[35,58]; (d) observation for hemoglobin at different depths[59]; (e) distribution of the blood oxygen saturation in a mouse brain[60]
    Portable PAM based on electronically controlled displacement stage. (a) Photograph of fast scanning PAM probe[64]; (b) cross-sectional photoacoustic patterns of different parts of human skin[64]; (c) AR-PAM based on fiber bundle illumination, including schematic diagram and physical map of the probe device[65]; (d) melanoma imaging in a nude mouse[65]; (e) diagram of OR-PAM device based on laser diode[66]; (f) imaging of the defective carbon fiber surface layer and deep carbon fiber embedded in fat[66]
    Portable PAM using GS galvanometer scanning. (a) PAM system schematic with adjustable light focus and the physical picture of the probe[71]; (b) imaging of subcutaneous blood vessels at the human wrist[71]; (c) schematic of PAM system with large field-of-view and physical picture of the probe[72]; (d) imaging of the mouse ear, iris, and brain microvessels[72]; (e) schematic of PAM system based on the rotational scanning[73]; (f) monitoring of vascular changes in a mouse tumor[73]; (g) schematic and photograph of the PAM device with hybrid scanning[77]; (h) vessels and oxygen saturation images of the mouse ear and back[77]
    Portable PAM using MEMS galvanometer scanning. (a) Diagram of the compactly designed handheld PAM system[78]; (b) imaging of human skin vessels[78]; (c) photograph of a photoacoustic probe with a mass of 162 g and a diameter of 17 mm[79]; (d) imaging of mouse ear, iris, and brain vessels[79]; (e) diagram of the probe with a volume of 22 mm×30 mm×13 mm and a mass of 20 g[37]; (f) imaging of human oral vessels[37]; (g) diagram of the photoacoustic pen[82]; (h) imaging of human oral vessels[82]
    Wearable PAM for the brain. (a) (b) Partial photograph and schematic diagram based on the suspended ball and head fixation device[103-104]; (c) photograph of the head-mounted cranial window with mass of 2 g and wide field-of-view of 5 mm×7 mm[106]; (d) device for monitoring neural activity in freely moving rat[107]; (e) small brain probe with mass of 8 g and diameter of 13 mm[108]; (f) schematic of the low-cost and miniaturized system[109]
    Miniaturized PAM based on multi-modality. (a) Schematic of a dual-modality system combining PAM and CFM[123]; (b) PAM (upper row) and CFM (lower row) imaging of animal bladder tissue[123]; (c) device diagram of OR-PAM and OCT dual-modality system based on rotary scanning[132]; (d) OR-PAM and OCT imaging of mouse ear (upper row) and human lower lip (lower row)[132]; (e) structure and photograph of the OR-PAM and OCT dual-modality probe with a mass of 35.4 g and a volume of 65 mm×30 mm×18 mm[133]; (f) OR-PAM and OCT imaging of mouse ear (upper row) and human oral lower lip (lower row)[133]; (g) schematic diagram and photograph of PAM-US-OCT three-modality probe[144]; (h) PAM (left), US (right), and OCT (medium) three-modality imaging of mouse ear blood vessels[144]
    • Table 1. Comparison of the imaging performance of GS mirror and MEMS mirror

      View table

      Table 1. Comparison of the imaging performance of GS mirror and MEMS mirror

      Scanner typeReferenceSystem size

      Imaging speed /Hz

      (B-scan)

      Imaging rangeLateral resolution /μmDemonstration
      GS mirror7040 mm×60 mm800800 μm7in vivo mouse ear
      71252 mm×2 mm8.9in vivo rooster’s wattle,human lip,and wrist
      72~100 cm×180 cm2514.5 mm×9 mm11.5ex vivo chicken breast tissue,in vivo mouse ear,iris,and brain
      73-74108.5 mm×1.5 mm10.4,4.2in vivo mouse ear,brain,eyes,and human mouth
      7513310 mm15in vivo rhesus monkey brain
      76100 mm×130 mm×140 mm40010 mm×10 mm10in vivo mouse brain
      7759 mm×30 mm×44 mm1288~1.7mm×5 mm6.2in vivo mouse organs
      MEMS mirror7880 mm×115 mm×150 mm2.5 mm×2 mm5in vivo mouse ear,human skin
      79diameter ~ 17 mm352.8 mm×2 mm12in vivo mouse ear,iris,brain,and human finger
      8060 mm×30 mm×20 mm~310.9 mm×0.9 mm10.4in vivo mouse ear,brain,and human lip
      378122 mm×30 mm×13 mm1002 mm×2 mm3.8in vivo mouse ear,abdomen,and human mouth
      82diameter~12 mm1002.4 mm18.2in vivo human mouth
    Tools

    Get Citation

    Copy Citation Text

    Mingli Sun, Chiye Li, Ruimin Chen, Junhui Shi. New Light in Microscopic Exploration: Portable Photoacoustic Microscopy (Invited)[J]. Laser & Optoelectronics Progress, 2024, 61(6): 0618017

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Microscopy

    Received: Dec. 5, 2023

    Accepted: Jan. 15, 2024

    Published Online: Mar. 22, 2024

    The Author Email: Junhui Shi (junhuishi@outlook.com)

    DOI:10.3788/LOP232623

    CSTR:32186.14.LOP232623

    Topics