Laser & Optoelectronics Progress, Volume. 61, Issue 1, 0130001(2024)
Dispersion Rate of Single-Stage Virtually Imaged Phased Array Spectrometer for Two-Dimensional Imaging of the Cornea and Lens (Invited)
Fig. 1. The effect of waist radius and cylindrical lens focal lengths on dispersion rate. (a) VIPA output spectra at
Fig. 2. The effect of F on dispersion rate. (a) Envelop of VIPA output spectra at
Fig. 3. The effect of VIPA tilting angle on dispersion rate. (a) The position of the P1 order of VIPA output spectra varing with
Fig. 4. The effect of camera pixel on dispersion rate. (a) Distribution of output optical when camera pixel is 1024×1024; (b) change of dispersion rate versus camera pixel value; (c) the one-dimensional spectra distribution curve at the red line position in Fig. 4(a) when camera pixel is 1024×1024 and 6000×6000, respectively
Fig. 5. The effect of waist radius, cylindrical lens focal lengths, focal lengths of spherical lens, and VIPA tilting angle on intensity difference and the dispersion rate. (a) The intensity difference between P2 and P1 at different waist radii and cylindrical lens focal length; (b) the intensity difference between P2 and P3 at different waist radii and cylindrical lens focal length; (c) the intensity difference between P2 and P1 at different focal lengths of spherical lens and VIPA tilting angle; (d) the intensity difference between P3 and P2 at different focal lengths of spherical lens and VIPA tilting angle; (e) the dispersion rate between P2 and P1 at different focal lengths of spherical lens and VIPA tilting angle; (f) the dispersion rate between P3 and P2 at different focal lengths of spherical lens and VIPA tilting angle
Fig. 7. Brillouin spectra of water and olive oil. (a)(b) Brillouin signals of water and oil when FSR of VIPA is 30 GHz, respectively; (c) Brillouin signals of water when FSR of VIPA is 20 GHz; (d) Brillouin signals of water when FSR of VIPA is 20 GHz
Fig. 8. Comparison of EMCCD and CMOS system parameters. (a) Extinction ratio; (b) dispersion rate, spectra resolution, measuring accuracy of Stokes, and contrast
Fig. 9. Measurements of Brillouin frequency shift of cornea and lens in an ex-vivo porcine eye. (a) Image based on measured frequency shifts at the center of cornea; (b) image based on measured frequency shifts of lens in red box region of Fig.9 (a) at a depth of 4 mm from the corneal surface
|
|
Get Citation
Copy Citation Text
Xingdao He, Jin Xu, Mingxuan Liu, Jiulin Shi. Dispersion Rate of Single-Stage Virtually Imaged Phased Array Spectrometer for Two-Dimensional Imaging of the Cornea and Lens (Invited)[J]. Laser & Optoelectronics Progress, 2024, 61(1): 0130001
Category: Spectroscopy
Received: Nov. 9, 2023
Accepted: Dec. 11, 2023
Published Online: Feb. 21, 2024
The Author Email: Xingdao He (xingdaohe@126.com), Jiulin Shi (jiulinshi@126.com)
CSTR:32186.14.LOP232462