Journal of Infrared and Millimeter Waves, Volume. 39, Issue 2, 163(2020)

Design and experiments of 94 GHz Gyrotron for non-lethal biological effects of millimeter wave radiation

Yuan-Yuan PAN1, Li-Na WANG2、*, Jian-Wei LIU2, Hui WANG2, and Shuang CHEN2
Author Affiliations
  • 1Department of Geriatric Cardiology, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital,Chengdu60072, China
  • 2School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu610054, China
  • show less
    Figures & Tables(13)
    The cavity structure and distribution of electric field relationship
    The normalized beam-wave coupling coefficient of the dominant and competitive modes varies with beam radius
    The starting current of the operating mode and the main competitive mode varies with the external magnetic field, where the beam voltage of 30 kV, beam radius of 3.3 mm and transverse-to-axial velocity ratio of 1.3 were selected
    The startup of multi-mode beam-wave interaction, where the beam voltage of 40 kV, beam current of 4A, transverse-to-axial velocity ratio of 1.3, beam radius of 3.3 mm
    The trajectory and structure of the designed MIG
    Overall diagram of electromagnetic wave transmission process on YOZ plane
    output window field distribution by Electromagnetic simulation
    Photo of the designed gyrotron with quasi-optical mode converter
    The field pattern on a piece of paper at 0.6m from the gyrotron output window
    Rabbit fixed on a wooden board
    • Table 1. Optimized beam parameters and MIG geometry

      View table
      View in Article

      Table 1. Optimized beam parameters and MIG geometry

      ParametersValues
      Beam voltage40 kV
      beam current4 A
      average radius3.3 mm

      Beam pitch ratio

      Cavity Magnetic field

      1.3

      3.540 T

    • Table 2. The relative power distribution of the 9 modes that form the Gaussian distribution

      View table
      View in Article

      Table 2. The relative power distribution of the 9 modes that form the Gaussian distribution

      TE4,3

      3%

      TE7,2

      11%

      TE10,1

      3%

      TE3,3

      11%

      TE6,2

      44%

      TE9,1

      11%

      TE2,3

      3%

      TE5,2

      11%

      TE8,1

      3%

    • Table 3. Data from the experimental test

      View table
      View in Article

      Table 3. Data from the experimental test

      ParametersValues
      Cathode voltage41.2 kV
      Cathode current3.6 A

      Anode voltage

      Frequency

      8 kV

      94.03 GHz

      Output power50.9 kW
    Tools

    Get Citation

    Copy Citation Text

    Yuan-Yuan PAN, Li-Na WANG, Jian-Wei LIU, Hui WANG, Shuang CHEN. Design and experiments of 94 GHz Gyrotron for non-lethal biological effects of millimeter wave radiation[J]. Journal of Infrared and Millimeter Waves, 2020, 39(2): 163

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Millimeter Wave and Terahertz Technology

    Received: Dec. 9, 2019

    Accepted: --

    Published Online: Apr. 29, 2020

    The Author Email: Li-Na WANG (linaw2018@outlook.com)

    DOI:10.11972/j.issn.1001-9014.2020.02.005