NUCLEAR TECHNIQUES, Volume. 47, Issue 6, 060303(2024)

Gamma radiation decomposition and the extraction performance of TODGA in kerosene medium

Shuying NONG1, Jiawei ZHENG2, Shuyi YANG2, Anbo YANG1, and Yan WU2、*
Author Affiliations
  • 1The 404 Company Limited, China National Nuclear Corporation, Jiayuguan 735112, China
  • 2School of Nuclear Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
  • show less
    Figures & Tables(10)
    Ultra-performance liquid chromatography and mass spectrum of unirradiated TODGA-kerosene solution
    Ultra-performance liquid chromatography and mass spectrum of the organic phase in TODGA-kerosene-nitric acid mixed system when the absorbed dose is 1 000 kGy (a) Without nitric acid, (b) 0.5 mol∙L-1 nitric acid in aqueous phase, (c) 3 mol∙L-1 nitric acid in aqueous phase, (d) 4 mol∙L-1 nitric acid in aqueous phase
    Change of TODGA radiolysis rate with the concentration of nitric acid when the absorbed dose is 1 000 kGy
    Ultra-performance liquid chromatography and mass spectrum of organic phase in TODGA-kerosene-3 mol∙L-1 nitric acid mixed system under different absorbed doses(a) Absorbed dose is 10 kGy, (b) Absorbed dose is 50 kGy, (c) Absorbed dose is 100 kGy
    Change of radiolysis rate of TODGA in TODGA-kerosene-3 mol∙L-1 nitric acid mixed system under different absorbed doses
    Schematic of the radiolysis path of TODGA
    Extraction results of metal ions by TODGA in the system with 3 mol∙L-1 nitric acid under different absorbed doses
    • Table 1. Peak area value of main radiolysis products of 3 mol∙L-1 nitric acid system under different absorbed doses

      View table
      View in Article

      Table 1. Peak area value of main radiolysis products of 3 mol∙L-1 nitric acid system under different absorbed doses

      出峰时间

      Peak time / min

      产物类型

      Product type

      10 kGy峰面积值

      10 kGy peak area value / Counts·min

      50 kGy峰面积值50 kGy peak area value / Counts·min100 kGy峰面积值100 kGy peak area value / Counts·min1 000 kGy峰面积值1 000 kGy peak area value / Counts·min
      0.73C16H33NO1.50×1052.58×1056.26×1046.78×103
      0.78C18H37NO21.70×1054.73×1055.64×1051.25×105
      0.87C18H37NO6.38×1046.76×1057.85×1057.29×104
      1.02C28H56N2O32.12×1053.39×1054.19×1051.05×105
    • Table 2. Peak area value of TODGA in TODGA-kerosene-3 mol∙L-1 nitric acid mixed system under different absorbed doses

      View table
      View in Article

      Table 2. Peak area value of TODGA in TODGA-kerosene-3 mol∙L-1 nitric acid mixed system under different absorbed doses

      吸收剂量

      Absorbed dose / kGy

      TODGA峰面积值

      TODGA peak area value / Counts·min

      01.87×106
      101.63×106
      501.14×106
      1001.22×106
    • Table 3. Forms of radiolysis products of TODGA in different solvents

      View table
      View in Article

      Table 3. Forms of radiolysis products of TODGA in different solvents

      辐解产物分子式

      Radiolysis products molecular formula

      煤油

      Kerosene

      正十二烷

      N-dodecane

      离子液体([N1888][NO3])

      Ionic liquid ([N1888][NO3])

      C16H35N
      C18H37NO2
      C18H37NO
      C28H56N2O3
      C28H55NO4
      C36H70N2O4
      C16H33NO
      C8H19N
      C9H19NO
      C17H35NO
      C19H39NO2
      C20H39NO4
      C48H96N2O3
    Tools

    Get Citation

    Copy Citation Text

    Shuying NONG, Jiawei ZHENG, Shuyi YANG, Anbo YANG, Yan WU. Gamma radiation decomposition and the extraction performance of TODGA in kerosene medium[J]. NUCLEAR TECHNIQUES, 2024, 47(6): 060303

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Nov. 10, 2023

    Accepted: --

    Published Online: Jul. 8, 2024

    The Author Email: WU Yan (吴艳)

    DOI:10.11889/j.0253-3219.2024.hjs.47.060303

    Topics