Optical Technique, Volume. 50, Issue 1, 81(2024)

Modulation parameters optimization and temperature compensation of CO detection system based on TDLAS

WANG Yinsong1、*, XIE Ruixin1, KONG Qingmei1, and GAO Jianqiang2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(17)

    [1] [1] Zhang Fucheng. Research on measurement of CO in power station boiler flue gas[D]. North China Electric Power University,2021.

    [2] [2] Zhou Peili, Tan Wen, Peng Zhimin. On-line measurement of CO concentration in flue gas based on TDLAS in mixed sampling mode[J]. Chinese Journal of Scientific Instrument,2019,40(11):233—240.

    [3] [3] Wang Jincheng, Liang Yuntao, Tian Fuchao. Research current situation of TDLAS gas detection technology and its application in coal mine[J]. Coal Mine Safety,2022,53(11):98—102.

    [4] [4] Dong Xueying. Research on carbon monoxide gas detection technology based on TDLAS system[D]. Harbin Engineering University,2019.

    [5] [5] Wang Linlin, Jia Ming. Simulation and analysis of second harmonic signal gas detection based on TDLAS technology[J]. Laser Journal,2020,41(03):25—28.

    [6] [6] Ye Weilin, Tu Zihan, Xiao Xupeng, et al. On multi-parameter influence of TDLAS detection system based on LabVIEW[J]. Journal of South China University of Technology (Natural Science Edition),2021,49(6):141—148.

    [8] [8] Supplee J M, Whittaker E A, Lenth W. Theoretical description of frequency modulation and wavelength modulation spectroscopy[J]. Applied Optics,1994,33(27).

    [9] [9] F. Alorifi, S. M. A. Ghaly, M. Y. Shalaby, M. A. Ali, M. O. Khan. Analysis and detection of a target gas system based on TDLAS LabVIEW[J]. Engineering, Technology & Applied Science Research,2019,9(3).

    [10] [10] Wang Xuemei, Liu Shi. Measurement of CO2 concentration based on wavelength modulation spectroscopy technology[J]. Journal of Atmospheric and Environmental Optics,2017,12(5):356—361.

    [11] [11] Yu Libin, Wang Fei, Zhang Lifang, et al. Effects of second harmonic modulation signal on of low-concentration ammonia[J]. Journal of Chinese Society of Power Engineering,2016,36(2):130—135.

    [13] [13] Zhang Zhirong, Wu Bian, Xia Hua, et al. Study on the temperature modified method for monitoring gas concentrations with tunable diode laser absorption spectroscopy[J]. Acta Phys. Sin,2013,62(23):183—189.

    [14] [14] Liu Ziqi, Yang Liufang. Gas sensor temperature compensating based on BP neural network[J]. Instrument Technique and Sensor,2017,(4):10—12.

    [15] [15] Du Jingyi, Yin Cong, Wang Weifeng, et al. Detection system of trace CO based on TDLAS and temperature and pressure compensation[J]. Optical Technology,2018,44(01):19—24.

    [16] [16] Xu Yuanzhong, Fu Yuekai, Wu Tiezhou. Estimating SOC of li-ion battery based on WOA-BP neural network[J]. Battery Bimonthly,2023,53 (1):38—42.

    [17] [17] Li Guolin, Liu Wenya, Ji Wenhai. Experimental research on near-infrared CO gas analysis system for natural gas[J]. Infrared and Laser Engineering,2019,48(S1):120—125.

    Tools

    Get Citation

    Copy Citation Text

    WANG Yinsong, XIE Ruixin, KONG Qingmei, GAO Jianqiang. Modulation parameters optimization and temperature compensation of CO detection system based on TDLAS[J]. Optical Technique, 2024, 50(1): 81

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Apr. 6, 2023

    Accepted: --

    Published Online: Jun. 28, 2024

    The Author Email: Yinsong WANG (wys@ncepu.edu.cn)

    DOI:

    CSTR:32186.14.

    Topics