Chinese Optics, Volume. 17, Issue 6, 1418(2024)

Design of a fast multi-dimensional imaging guidance optical system based on array optics

Hao-dong SHI1、*, Qi LU1,2, Yi-wu ZHAO1, Jia-yu WANG1,2, Xiao ZHAO3, Ying-chao LI1, and Qiang FU1
Author Affiliations
  • 1Jilin Provincial Key Laboratory of Space Optoelectronics Technology, Changchun University of Science and Technology, Changchun 130022, China
  • 2School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130022, China
  • 3Northeast Industries Group Co., Ltd. Changchun 130103, China
  • show less
    Figures & Tables(13)
    Schematic diagram of the proposed fast multi-dimensional imaging guidance optical system
    Symbolic diagram of the optical system
    The relationship between the aperture of the sub-unit of the microlens array and the telescope unit magnification at different spatial resolutions
    Transmittance curves of spectral filter array channel
    Schematic diagram of detector’s area division
    Schematic diagram of telecentric imaging optical path of microlens array
    Three-dimensional diagram of the designed optical system
    MTF of 16 spectral channels of the optical system
    Distortion map of 16 spectral channels in the normalized field of view of the optical system
    The energy concentration curves of 16 spectral channels of the optical system
    • Table 1. Technical index of the optical system

      View table
      View in Article

      Table 1. Technical index of the optical system

      参数数值
      有效焦距/mm150
      入瞳孔径/mm17.25
      空间分辨率/m0.25@10 km
      视场/mrad5.34×5.34
      工作波长/nm450~706
      光谱分辨率/nm16
      探测器靶面4096×3000
      像元尺寸/μm3.45
    • Table 2. Optical system tolerance settings

      View table
      View in Article

      Table 2. Optical system tolerance settings

      对象公差类型数值
      望远单元主镜次镜
      XY方向偏心/mm±0.08±0.08
      Z方向厚度/mm±0.025±0.025
      XY方向倾斜/(°)±0.1±0.1
      二次曲率系数±0.001±0.001
      曲率半径/mm±0.001±0.001
      微透镜阵列位置精度偏心/mm±0.005
      厚度/mm±0.025
      单元透镜倾斜/(′)±0.3
      不规则度±0.2
      曲率半径/mm±0.01
      光谱滤光阵列位置精度偏心/mm±0.005
      光谱通道倾斜/(′)±0.3
      不规则度±0.2
      厚度/mm±0.01
      常规透镜折射率±0.0008
      光圈数±2
      厚度/mm±0.025
      不规则度±0.25
      阿贝数/%0.08
      元件倾斜/(′)±0.8
      表面倾斜/(′)±0.8
      元件偏心/mm±0.008
      表面偏心/mm±0.008
    • Table 3. Monte Carlo tolerance analysis results

      View table
      View in Article

      Table 3. Monte Carlo tolerance analysis results

      通道RMS光斑半径/μm通道RMS光斑半径/μm
      90%90%
      通道15.936通道94.737
      通道24.927通道102.899
      通道34.786通道112.994
      通道45.723通道124.938
      通道54.880通道135.885
      通道63.087通道 145.047
      通道73.007通道155.296
      通道84.895通道165.821
    Tools

    Get Citation

    Copy Citation Text

    Hao-dong SHI, Qi LU, Yi-wu ZHAO, Jia-yu WANG, Xiao ZHAO, Ying-chao LI, Qiang FU. Design of a fast multi-dimensional imaging guidance optical system based on array optics[J]. Chinese Optics, 2024, 17(6): 1418

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Nov. 14, 2023

    Accepted: --

    Published Online: Jan. 14, 2025

    The Author Email:

    DOI:10.37188/CO.2023-0206

    Topics