Chinese Journal of Liquid Crystals and Displays, Volume. 37, Issue 7, 849(2022)

Electronic design of space-based LCVR measurement system

Wei HUANG1,2,3, Jia-ben LIN1,2,3、*, Jun-feng HOU1,2,3, Yang ZHANG1,2,3, Xiao-ming ZHU1,2,3, Yuan-yong DENG1,2,3, and Dong-guang WANG1,2
Author Affiliations
  • 1National Astronomical Observatories,Chinese Academy of Sciences,Beijing 100101,China
  • 2Key Laboratory of Solar Activity,Chinese Academy of Sciences,Beijing 100101,China
  • 3University of Chinese Academy of Sciences,Beijing 100049,China
  • show less
    Figures & Tables(16)
    Structure of LCVR
    Retardation-voltage curve of LCVR
    Optical design of the space-based LCVR measurement system
    Driving waveform of LCVR
    Circuit function
    Amplifier circuit of signal polarity conversion
    Wheatstone differential temperature measurement circuit
    Optical structure diagram of LCVR tester
    Constant temperature control accuracy in different working frequency
    Physical object of circuit system
    Retardation difference before and after mechanical test
    Intensity-voltage variations measured in different thermal tests
    EMC test
    • Table 1. Positive and negative output measurement(V)

      View table
      View in Article

      Table 1. Positive and negative output measurement(V)

      v+FlukeVictorv-FlukeVictor
      0.50.4990.499 0-0.5-0.488-0.488 2
      1.00.9970.997 8-1.0-0.997-0.997 8
      1.51.4971.498 1-1.5-1.497-1.497 5
      2.01.9951.997 0-2.0-1.995-1.996 3
      2.52.4932.495-2.5-2.493-2.494
      3.02.9922.994-3.0-2.992-2.993
      3.53.4903.492-3.5-3.490-3.492
      4.03.9903.991-4.0-3.990-3.991
      4.54.4804.490-4.5-4.480-4.491
      5.04.9804.998-5.0-4.980-4.991
    • Table 2. Output stability

      View table
      View in Article

      Table 2. Output stability

      vsetVppvsetVpp
      FlukeVictorFlukeVictor
      ±0.50.974 00.974 4±30.994 60.995 6
      ±10.994 00.995 6±3.50.994 20.995 4
      ±1.50.996 00.997 0±40.995 00.995 5
      ±20.995 00.996 6±4.50.991 10.995 7
      ±2.50.994 40.995 6±50.992 00.997 8
    • Table 3. Frequency stability

      View table
      View in Article

      Table 3. Frequency stability

      TimesfoutTimesfout
      1599.995599.99
      2599.996599.99
      3600.007599.99
      4600.008600.00
    Tools

    Get Citation

    Copy Citation Text

    Wei HUANG, Jia-ben LIN, Jun-feng HOU, Yang ZHANG, Xiao-ming ZHU, Yuan-yong DENG, Dong-guang WANG. Electronic design of space-based LCVR measurement system[J]. Chinese Journal of Liquid Crystals and Displays, 2022, 37(7): 849

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Dec. 22, 2021

    Accepted: --

    Published Online: Jul. 7, 2022

    The Author Email: Jia-ben LIN (jiabenlin@bao.ac.cn)

    DOI:10.37188/CJLCD.2021-0335

    Topics