Chinese Journal of Lasers, Volume. 48, Issue 9, 0901006(2021)

Precise Correction for Crystal Axis Angle of KDP Crystal Element

Shuai Zhang, Bojia Jin*, Xiangfeng Wang, Xiangyang Lei, Jian Wang, and Qiao Xu
Author Affiliations
  • Research Center of Laser Fusion, China Academy Engineering Physics, chengdu, Sichuan 610000, China
  • show less
    Figures & Tables(15)
    Schematic of crystal axis angle
    Schematic of diamond cutting principle
    Program block diagram of crystal axis angle error adjustment
    Principle of in-situ measuring of crystal axis angle error
    Data processing
    In-situ drift
    Sucker angle adjustment tool. (a) Physical photograph; (b) operating interface; (c) error of different adjustment values; (d) home error
    Crystal axis correction procedure
    In-situ testing results of crystal surface of sample 1#. (a) Before cutting; (b) after cutting
    Angle between two surfaces of sample 1# after correction
    Test result of sample 1#
    Relationship between calibration error and element aperture
    • Table 1. Sample information

      View table

      Table 1. Sample information

      SampleTypeThickness /mmCrystal axis angle error /μrad
      1#Third harmonic generation crystal14.4+3811.5
      2#Third harmonic generation crystal14.4+2143.7
      3#Second harmonic generation crystal14.7+3878.0
    • Table 2. Technical specification of LK-G10 type laser displacement sensor

      View table

      Table 2. Technical specification of LK-G10 type laser displacement sensor

      ParameterValue
      Measurement range/mm-1-1
      Linearity error /μm0.6
      Repeatability precision /μm0.01
    • Table 3. Relevant parameters of three sample pieces during the iteration unit: μrad

      View table

      Table 3. Relevant parameters of three sample pieces during the iteration unit: μrad

      Iteration turn1#2#3#
      AdjustmentvalueDeviationvalueAdjustmentvalueDeviationvalueAdjustmentvalueDeviationvalue
      1-3871.46-59.96-2172.57-28.87-3887.94-9.94
      2-3805.775.73-2143.81-0.11-3884.91-6.91
      3-3811.58-0.08-2143.630.07-3878.04-0.04
    Tools

    Get Citation

    Copy Citation Text

    Shuai Zhang, Bojia Jin, Xiangfeng Wang, Xiangyang Lei, Jian Wang, Qiao Xu. Precise Correction for Crystal Axis Angle of KDP Crystal Element[J]. Chinese Journal of Lasers, 2021, 48(9): 0901006

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: laser devices and laser physics

    Received: Oct. 18, 2020

    Accepted: Nov. 27, 2020

    Published Online: Apr. 26, 2021

    The Author Email: Jin Bojia (zsbfsj@126.com)

    DOI:10.3788/CJL202148.0901006

    Topics