Laser & Optoelectronics Progress, Volume. 54, Issue 8, 80101(2017)

Monitoring of Mercury Emission in Coal-Fired Power Plant Based on Zeeman Atomic Absorption Spectrometry

Zhang Yong1,2,3、*, Si Fuqi1, Li Chuanxin1, Zeng Yi1, Liu Wenqing1, and Zhou Haijin1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    References(27)

    [1] [1] Hansen J C, Danscher G. Organic mercury: An environmental threat to the health of exposed societies[J]. Reviews on Environmental Health, 1997, 12(2): 107-116.

    [2] [2] Schroeder W H, Munthe J. Atmospheric mercury - an overview[J]. Atmospheric Environment, 1998, 32(5): 809-822.

    [3] [3] Lindberg S, Bullock R, Ebinghaus R, et al. A Synthesis of progress and uncertainties in attributing the sources of mercury in deposition[J]. AMBIO: A Journal of the Human Environment, 2007, 36(1): 19-32.

    [4] [4] Li Jinlan, Luo Jinjing, Zhang Longdong, et al. Determination of trace atmospheric mercury by two-stage gold amalgamation cold vapor atomic fluorescence spectrometry method[J]. Journal of Xiamen University (Natural Science), 2011, 50(3): 574-578.

    [5] [5] Ivannikova N V, Shiryaeva O A, Karpov Y A. Atomic absorption determination of mercury in solid samples of placer gold[J]. Inorganic Materials, 2010, 46(14): 1499-1502.

    [6] [6] Zhang Y L, Adeloju S B. Speciation of mercury in fish samples by flow injection catalytic cold vapour atomic absorption spectrometry[J]. Analytica Chimica Acta, 2012, 721(7): 22-27.

    [7] [7] Pacyna E G, Pacyna J M, Steenhuisen F, et al. Global anthropogenic mercury emission inventory for 2000[J]. Atmospheric Environment, 2006, 40(22): 4048-4063.

    [8] [8] Wang Sheng, Liu Hongzhi, Chen Hui. Comparative analysis on control technique of mercury discharge in coal-fired power plant at home and abroad[J]. China Environmental Protection Industry, 2012, 7: 42-46.

    [9] [9] AMAP/UNEP. Technical background report to the global atmospheric mercury assessment[R]. Nairobi, Kenya: Arctic Monitoring and Assessment Programme/UNEP Chemicals Branch, 2008: 159.

    [10] [10] Zhong Li, Xiao Ping, Jiang Jianzhong, et al. Study on several measuring methods of mercury emission from coal-fired power plants[J]. Proceedings of the CSEE, 2012, 32(S): 158-163.

    [11] [11] Ministry of Environmental Protection, General Administration of Quality Supervision, Inspection and Quanrantine. Emission standard of air pollutants for thermal power plants: GB 13223-2011[S]. Beijing: China Environmental Science Press, 2011: 3-4.

    [12] [12] Liu Jin, Si Fuqi, Zhou Haijin, et al. Estimation of sulfur dioxide emission from power plant using imaging differential optical absorption spectroscopy technique[J]. Acta Optica Sinica, 2015, 35(6): 0630003.

    [13] [13] Li Suwen, Wei Minhong, Dai Haifeng, et al. Reconstruction of spatial distributions of industrial emissions based on scaning multi-axis DOAS tomography[J]. Acta Optica Sinica, 2015, 35(4): 0401003.

    [14] [14] Yu Minjie, Liu Minghui, Dong Zuoren, et al. Study on measuring concentration of ammonia and sulphur dioxide by differential optical absorption spectrometry based on fast Fourier transform[J]. Chinese J Lasers, 2015, 42(9): 0915001.

    [15] [15] Wang Qingfeng. Study on oxidized mercury reduction inhibition in wet FGD system and the stability of mercury in desulfurzation gypsum[D]. Hangzhou: Zhejiang University, 2015.

    [16] [16] Li Chuanxin, Si Fuqi, Zhou Haijin, et al. New transverse Zeeman effect method for mercury detection based on common mercury lamp[J]. Acta Physica Sinica, 2014, 63(7): 074202.

    [17] [17] Frentiu T, Mihaltan A I, Ponta M, et al. Mercury determination in non- and biodegradable materials by cold vapor capacitively coupled plasma microtorch atomic emission spectrometry[J]. Journal of Hazardous Materials, 2011, 193(2): 65-69.

    [19] [19] Deng Bo, He Huakun. Atomic absorption spectral analysis[M]. Beijing: Chemical Industry Press, 2004: 1-20.

    [20] [20] Hadeishi T, Church D A, Mclaughlin R D. Mercurymonitor for ambient air[J]. Science, 1975, 187(4174): 348-349.

    [21] [21] Zhang Jianhua. Study on mercuryre-emission from the liquors of wet flue gas desulfrization[D]. Beijing: North China Electric Power University, 2011.

    [22] [22] Hadeishi T, Mclaughlin R D. Hyperfine Zeeman effect atomic absorption spectrometer for mercury[J]. Science, 1971, 174(4007): 404-407.

    [23] [23] Huber M L, Laesecke A, Friend D G. Correlation for the vapor pressure of mercury[J]. Industrial & Engineering Chemistry Research, 2006, 45(21): 7351-7361.

    [24] [24] Yang Kai. Flue gas mercury monitoring technology and equipment in stationary pollution source[M]. Beijing: China Electric Power Press, 2012: 8-75.

    [25] [25] Yang Hongmin, Liu Kunlei, Cao Yan, et al. Demercurization property of flue gas desulfurization installations in power plants[J]. Journal of Power Engineering, 2006, 26(4): 554-567.

    [26] [26] Wang Yunjun, Duan Yufeng,Yang Liguo, et al. Experimental study on mercury removal by combined wet flue gas desulphurization with electrostatic precipitator[J]. Proceedings of the CSEE, 2008, 28(29): 64-69.

    [27] [27] Li Shaohua, Xu Yingjian,Wang Hu, et al. Simulation study on the take off mercury and sulfur performance in the wet flue gas desulfurization system[J]. Boiler Technology, 2014, 45(6): 72-76.

    Tools

    Get Citation

    Copy Citation Text

    Zhang Yong, Si Fuqi, Li Chuanxin, Zeng Yi, Liu Wenqing, Zhou Haijin. Monitoring of Mercury Emission in Coal-Fired Power Plant Based on Zeeman Atomic Absorption Spectrometry[J]. Laser & Optoelectronics Progress, 2017, 54(8): 80101

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Atmospheric Optics and Oceanic Optics

    Received: Feb. 28, 2017

    Accepted: --

    Published Online: Aug. 2, 2017

    The Author Email: Zhang Yong (yongzhang@aiofm.ac.cn)

    DOI:10.3788/lop54.080101

    Topics