Acta Optica Sinica, Volume. 44, Issue 23, 2311004(2024)

Effect of Minimum Baseline Length on Integrated Interferometric Systems

Zhen Zhang1,2,3,4, Xuefeng Zeng1,2,3,4、*, Yang Liu1,2,3,4、**, Lingjie Wang1,2,3,4、***, and Xuejun Zhang1,2,3,4
Author Affiliations
  • 1Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, Jilin , China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • 3State Key Laboratory of Applied Optics, Changchun 130033, Jilin , China
  • 4Key Laboratory of Advanced Manufacturing Technology of Optical Systems, Chinese Academy of Sciences, Changchun 130033, Jilin , China
  • show less
    Figures & Tables(13)
    Structure diagram of SPIDER
    Schematic diagram of microlens array structure
    Schematic diagram of first and last pairing
    Observation objective. (a) Objective 1; (b) objective 2; (c) objective 3
    Recovery results of observation objective 1 at different minimum baseline lengths (linear field of view 200 m). (a) 1 mm; (b) 2 mm; (c) 3 mm; (d) 4 mm; (e) 5 mm; (f) 6 mm
    Recovery results of observation objective 2 at different minimum baseline lengths (linear field of view 200 m). (a) 1 mm; (b) 2 mm; (c) 3 mm; (d) 4 mm; (e) 5 mm; (f) 6 mm
    Recovery results of observation objective 3 at different minimum baseline lengths (linear field of view 200 m). (a) 1 mm; (b) 2 mm; (c) 3 mm; (d) 4 mm; (e) 5 mm; (f) 6 mm
    Recovery results of observation objective 1 at different minimum baseline lengths (linear field of view 100 m). (a) 1 mm; (b) 2 mm; (c) 3 mm; (d) 4 mm; (e) 5 mm; (f) 6 mm
    Recovery results of observation objective 2 at different minimum baseline lengths (linear field of view 100 m). (a) 1 mm; (b) 2 mm; (c) 3 mm; (d) 4 mm; (e) 5 mm; (f) 6 mm
    Recovery results of observation objective 3 at different minimum baseline lengths (linear field of view 100 m). (a) 1 mm; (b) 2 mm; (c) 3 mm; (d) 4 mm; (e) 5 mm; (f) 6 mm
    • Table 1. Simulation parameter of SPIDER system

      View table

      Table 1. Simulation parameter of SPIDER system

      ParameterValue
      Wavelength λ /nm1600
      Observation distance z /km600
      Microlens diameter D /mm1
      Microlens focal length f /mm10
      Number of interference arms M87
      Number of microlenses per column N104
      Linear field X /m

      200

      100

      Angular field θFOV /(°)1.14'0.57'
    • Table 2. RMSE and PSNR corresponding to the recovered image at a field of view of 200 m

      View table

      Table 2. RMSE and PSNR corresponding to the recovered image at a field of view of 200 m

      ImageEvaluation metricLens distance /mm
      123456
      Fig. 4(a)RMSE89.894589.6899119.0260113.4020119.1140112.0430
      PSNR /dB9.05619.07596.61797.03846.61157.1431
      Fig. 4(b)RMSE96.900296.7268129.5950126.1650127.0960128.5600
      PSNR /dB8.40438.41995.87906.11206.04825.9487
      Fig. 4(c)RMSE107.3200107.2600138.9920128.5290130.9190133.2670
      PSNR /dB7.51727.52205.27105.95085.79075.6364
      AverageRMSE98.038297.8922129.2040122.6990125.7100124.6230
      PSNR /dB8.32598.33935.92266.36716.15016.2427
    • Table 3. RMSE and PSNR corresponding to the recovered image at a field of view of 100 m

      View table

      Table 3. RMSE and PSNR corresponding to the recovered image at a field of view of 100 m

      ImageEvaluation metricLens distance /mm
      123456
      Fig. 4(a)RMSE89.650790.103389.867690.1259114.9750119.1210
      PSNR /dB9.07979.03609.05879.03386.91876.6110
      Fig. 4(b)RMSE97.008797.127697.065897.2557129.2460129.8130
      PSNR /dB8.39468.38408.38958.37255.90255.8644
      Fig. 4(c)RMSE111.5010107.4812107.2060107.4350139.2170139.1460
      PSNR /dB7.18537.50427.52657.50795.25705.2614
      AverageRMSE99.386898.237398.046598.2722127.8130129.3600
      PSNR /dB8.21998.30818.32498.30476.02615.9123
    Tools

    Get Citation

    Copy Citation Text

    Zhen Zhang, Xuefeng Zeng, Yang Liu, Lingjie Wang, Xuejun Zhang. Effect of Minimum Baseline Length on Integrated Interferometric Systems[J]. Acta Optica Sinica, 2024, 44(23): 2311004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Jul. 25, 2024

    Accepted: Sep. 2, 2024

    Published Online: Dec. 16, 2024

    The Author Email: Zeng Xuefeng (zxf@ciomp.ac.cn), Liu Yang (liu9527aaa@163.com), Wang Lingjie (wanglingjie@126.com)

    DOI:10.3788/AOS241355

    CSTR:32393.14.AOS241355

    Topics