Laser & Optoelectronics Progress, Volume. 51, Issue 3, 31204(2014)

Calibration of Foci-Meter Based on Talbot-Moiré Interferometer

Zhao Qi1、*, Jiang Zewei1, Meng Qing′an1, Li Yiguo1, Fan Hongying1, Hu Shaoyun1, Li Jianxin2, He Yong2, and Yang Jie3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    References(13)

    [1] [1] De Angelis M, De Nicola S, Ferraro P, et al.. A new approach to high accuracy measurement of the focal lengths of lenses using a digital Fourier transform [J]. Opt Commun, 1997, 136(1): 370-374.

    [2] [2] Duan Yaxuan, Chen Yongquan, Zhao Jianke, et al.. Focal length testing method of long focal length laser optical system [J]. Chinese J Lasers, 2013, 40(4): 0408005.

    [3] [3] Sun Guozheng, Guo Hongqi. Optical testing method for large convex surface [J]. Optical Technique, 2006, 32(S1): 631-362.

    [5] [5] Kafri O. Noncoherent method for mapping phaser objects [J]. Opt Lett, 1980, 5(12): 555-557.

    [6] [6] Y Nakano, K Murata. Talbot interferometry for measuring the focallength of a lens [J]. Appl Opt, 1985, 24(19): 3162-3166.

    [8] [8] T G Parham, T McCarville, M A Johnson, et al.. Focal length measurements for the National Ignition Facility large lenses [C]. Optical Fabricaton and Testing Conference, Tucson, Arizona, 2002: OWD8.

    [9] [9] B DeBoo, J Sasian. Precise focal-length measurement technique witha reflective Fresnel-zone hologram [J]. Appl Opt, 2003, 42(19): 3903-3909.

    [10] [10] Hou Changlun, Sun Chen, Bai Jian, et al.. Scanning method for focal length measurement of large aperture long focal mirror and lens [J]. Acta Metrologica Sinica, 2004, 25(3): 219-222.

    [11] [11] Lü Bo, Liu Weiqi, Kang Yusi, et al.. Design of all spherical surfaces zoom lithographic system [J]. Acta Optica Sinica, 2013, 33(6): 0622001.

    [12] [12] Zhao Qi, Jiang Zhewei, He Yong, et al.. Development and calibration of shearing interferometer [J]. Laser & Optoelectronics Progress, 2012, 49(4): 041204.

    [13] [13] Wang Shengyun, Zheng Xue, Yang Hong, et al.. Explanation of calibration specification for IR optical focal length measuring equipment [J]. Journal of Applied Opitcs, 2007, 28(6): 806-808.

    CLP Journals

    [1] Ai Yongxu, Zhou Xiang, Du Hubing, Guo Jiayu, Yang Tao, Zhao Lei. Shadow Moiré Using Talbot Effect Under Point Light Illumination[J]. Acta Optica Sinica, 2016, 36(4): 412003

    Tools

    Get Citation

    Copy Citation Text

    Zhao Qi, Jiang Zewei, Meng Qing′an, Li Yiguo, Fan Hongying, Hu Shaoyun, Li Jianxin, He Yong, Yang Jie. Calibration of Foci-Meter Based on Talbot-Moiré Interferometer[J]. Laser & Optoelectronics Progress, 2014, 51(3): 31204

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Oct. 2, 2013

    Accepted: --

    Published Online: Mar. 3, 2014

    The Author Email: Qi Zhao (zhaoqi2156@163.com)

    DOI:10.3788/lop51.031204

    Topics