Journal of Infrared and Millimeter Waves, Volume. 42, Issue 6, 883(2023)

A 0.3 W@4.2 K high-capacity lightweight cryogenic system for space BIB detection

Jin-Jian CHU1,2, Shao-Shuai LIU1,2、*, Peng WANG1,2, Lei DING1, Yun-Long XIAO1,2, Wang YIN1,2, Zhi-Chao CHEN1, Xin-Quan SHA1, Zhen-Hua JIANG1,2, and Yi-Nong WU1,2、*
Author Affiliations
  • 1Shanghai Institute of Technical Physics,Chinese Academy of Sciences,Shanghai 200083,China
  • 2University of Chinese Academy of Sciences,Beijing 100049,China
  • show less
    References(36)

    [2] GUO Jia-Xiang, XIE Run-Zhang, WANG Peng et al. Infrared photodetectors for multidimensional optical information acquisition[J]. J.Infrared Millim and Waves, 41, 40-60(2022).

    [3] Xiao Y., Zhu H., Deng K. et al. Progress and challenges in blocked impurity band infrared detectors for space-based astronomy, Sci. China-Phys. Mech. Astron, 65, 287301(2022).

    [4] SHI Qian, ZHANG Shu-Kui, WANG Jian-Lu et al. Progress on nBn infrared detectors[J]. J. Infrared Millim.Waves, 41, 139-150(2022).

    [7] Gan Z.-H., Wang B., Liu D.-L. et al. Status and development trends of space mechanical refrigeration system at liquid helium temperature, Journal of Zhejiang University. Engineering Science, 46, 2160-2177(2012).

    [8] GAN Zhi-hua, TAO Xuan, LIU Dong-li et al. Development status of space cryogenic technology atliquid helium temperature in Japan. Journal of Zhejiang University. Engineering Science, 49, 1821-1835(2015).

    [12] Ross, Jr, R et al. NASA's Advanced Cryocooler Technology Development Program (ACTDP).[J]. AIP Conference Proceedings, 823, 607-614(2006).

    [15] Petach M, Durand D, Michaelian M et al. MIRI cryocooler system design update[C], 9-12(2011).

    [17] Zhou Zhenjun. Research on 4K throttling cryocooler with high frequency multistage pulse tube pre-cooling[D]. Technical Institute of Physics and Chemistry(2014).

    [25] Wei Dai, Yu Guoyao, Zhu Shanglong et al. A 300 Hz thermoacoustically-driven pulse tube cryocooler for temperature below 100 K, Applied Physics Letters, 90, 024104(2007).

    [26] YIN Wang, WU Wenting, HUI Hejun et al. Theoretical and Experimental Study on the Length-Diameter of the Regenerator in the Low Temperature Section of a 15 K Thermal-Coupled Two-Stage Pulse Tube Cryocooler[J]. Journal of Xi'an Jiaotong University, 56, 184-194(2022).

    Tools

    Get Citation

    Copy Citation Text

    Jin-Jian CHU, Shao-Shuai LIU, Peng WANG, Lei DING, Yun-Long XIAO, Wang YIN, Zhi-Chao CHEN, Xin-Quan SHA, Zhen-Hua JIANG, Yi-Nong WU. A 0.3 W@4.2 K high-capacity lightweight cryogenic system for space BIB detection[J]. Journal of Infrared and Millimeter Waves, 2023, 42(6): 883

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Mar. 8, 2023

    Accepted: --

    Published Online: Dec. 26, 2023

    The Author Email: Shao-Shuai LIU (liushaoshuai@mail.sitp.ac.cn), Yi-Nong WU (liushaoshuai@mail.sitp.ac.cn)

    DOI:10.11972/j.issn.1001-9014.2023.06.022

    Topics