Acta Optica Sinica, Volume. 42, Issue 5, 0514001(2022)

Design and Thermal Effect Analysis of LD Pumped Er,Yb∶glass Slab Multi-pass Amplifier

Kexin Zhang1,2, Kaixin Wang1,2, and Chunqing Gao1,2、*
Author Affiliations
  • 1School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China
  • 2Key Laboratory of Information Photonics Technology, Ministry of Industry and Information Technology, Beijing 100081, China
  • show less
    Figures & Tables(11)
    Geometry model of Er,Yb∶glass slab
    Schematic view of the Er,Yb∶glass multi-pass amplifier
    Relationship between output energy and pump power in multi-pass amplifier
    Three-dimensional temperature distribution of the slab medium on the y-z plane at different pump modes. (a) Single-ended pump; (b) dual-ended pump
    Maximum temperature and stress of Er,Yb∶glass slab samples
    Thermodynamic results at different pump power. (a) Maximum temperature; (b) maximum stress
    Thermodynamic results along the z axis at different pump beam waist radius. (a) Temperature distribution; (b) stress distribution
    OPD distribution fitting results along the y axis direction
    • Table 1. Parameters used in the simulation

      View table

      Table 1. Parameters used in the simulation

      ParameterValue
      Energy level degeneracyγ=2
      Stimulated emission cross sectionσe=0.8×10-20 cm2
      Fluorescence lifetimeτf=7.9 ms
      Quantum efficiencyηq=0.95
      Stokes factorηs=0.606
      Pump absorption efficiencyηabs=0.95
      Incident seed energy densityDin=140 J/m2
      Laser beam cross section areaS=0.5 mm2
      Gain lengthl≈200 mm
    • Table 2. Physical characteristic parameters of the Er,Yb∶glass laser medium

      View table

      Table 2. Physical characteristic parameters of the Er,Yb∶glass laser medium

      ParameterValue
      Thermal conductivityK=0.85 W/(m·K)
      Young’s ModulusE=67 GPa
      Poisson ratioμ=0.24
      Thermal expansion coefficientαT=8.8×10-6 K-1
      Thermal optical coefficientdn/dt=-2.1×10-6 K-1
      Cooling water temperatureTc=18 ℃
      Room temperatureT0=22 ℃
      Convective heat coefficient of airh0=27.5 W/(m2·K)
      Pump beam waist radiusω0=400 μm
      Thermogenesis efficiencyη=0.3935
      Absorption coefficientα=6 cm-1
      Refractive indexn=1.532
    • Table 3. Geometric parameters of Er,Yb∶glass slab sample

      View table

      Table 3. Geometric parameters of Er,Yb∶glass slab sample

      SampleLengthL /mmWidthw /mmThicknesst /mm
      13041
      23051
      33051.2
      43051.6
    Tools

    Get Citation

    Copy Citation Text

    Kexin Zhang, Kaixin Wang, Chunqing Gao. Design and Thermal Effect Analysis of LD Pumped Er,Yb∶glass Slab Multi-pass Amplifier[J]. Acta Optica Sinica, 2022, 42(5): 0514001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Lasers and Laser Optics

    Received: Aug. 3, 2021

    Accepted: Sep. 8, 2021

    Published Online: Mar. 8, 2022

    The Author Email: Chunqing Gao (gao@bit.edu.cn)

    DOI:10.3788/AOS202242.0514001