Acta Photonica Sinica, Volume. 53, Issue 9, 0911003(2024)

A Weighted Guide Filtering Demosaicing Method with Weighting Coefficients Based on RGB-NIR Filter Array

Xin WU1,2, Baoteng XU2, Jialin LIU2, Wei ZHOU2, and Xibin YANG1,2、*
Author Affiliations
  • 1School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Suzhou 215163, China
  • 2Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
  • show less
    Figures & Tables(12)
    Algorithm interpolation process
    RGB-NIR filter array
    Visual comparison of some images
    RGB-NIR sensor camera image acquisition system and spectral curves of illumination light sources
    Images taken with infrared light source irradiation
    Images taken without infrared light source irradiation
    Schematic diagram of the image acquisition system and localized enlarged view and image acquisition system physical diagram
    RGB-NIR sensor camera image processing flow and images captured by different cameras
    • Table 1. PSNR(CPSNR) comparison of algorithms

      View table
      View in Article

      Table 1. PSNR(CPSNR) comparison of algorithms

      FigureBilinearAIuLGRI-basedProposed
      RGBNIRRGBNIRRGBNIRRGBNIR
      Average30.0529.2633.2932.4337.6634.0238.0434.90
      Butterfly29.5431.6532.6734.1437.2436.8037.7837.74
      Butterfly233.4232.4639.7838.1543.9539.3044.2339.92
      Chart26.3427.4834.1334.3939.2935.4439.9836.65
      Chart226.9927.8434.3635.1640.0737.4240.8037.82
      Chart325.3525.5032.5034.7240.3137.8540.2339.73
      Cloth27.5824.7329.0226.3633.0827.1733.7927.81
      Cloth232.9528.0533.9228.8835.8129.7536.6230.98
      Cloth329.6927.9331.3729.6935.2030.5235.9431.18
      Doll30.8729.5732.3030.7134.4130.6134.7031.94
      Doll233.5229.2934.4529.5737.6029.9737.9230.87
      Fan32.4533.0534.2335.9438.1936.9338.1138.04
      Fan234.6933.9436.1736.5339.9637.9440.0339.14
      Fan329.3529.2831.1830.7734.1832.5234.6532.96
      Origami31.3731.0134.7732.8242.3937.8642.1938.48
      Paint27.9727.8229.7329.6233.2331.6133.3932.06
      Spray28.7928.6032.1031.3637.6732.6038.2833.04
    • Table 2. Comparison of NIQE indicator when the infrared light source is turned on

      View table
      View in Article

      Table 2. Comparison of NIQE indicator when the infrared light source is turned on

      AlgorithmScene 1Scene 2Scene 3Average
      RGBNIRRGBNIRRGBNIRRGBNIR
      AIuLG9.733.9710.774.299.154.079.884.11
      RI-based7.363.646.833.975.904.056.703.89
      Proposed5.813.755.973.804.843.765.543.77
    • Table 3. Comparison of NIQE indicator when the infrared light source is turned off

      View table
      View in Article

      Table 3. Comparison of NIQE indicator when the infrared light source is turned off

      AlgorithmScene 1Scene 2Scene 3Average
      RGBNIRRGBNIRRGBNIRRGBNIR
      AIuLG9.107.449.577.758.896.569.197.25
      RI-based6.224.946.175.506.256.236.215.56
      Proposed5.254.075.484.465.255.165.334.56
    • Table 4. Comparison of absolute values of average NIQE changes before and after turning off the infrared light source

      View table
      View in Article

      Table 4. Comparison of absolute values of average NIQE changes before and after turning off the infrared light source

      AlgorithmAverage
      RGBNIR
      AIuLG0.693.14
      RI-based0.491.67
      Proposed0.210.79
    Tools

    Get Citation

    Copy Citation Text

    Xin WU, Baoteng XU, Jialin LIU, Wei ZHOU, Xibin YANG. A Weighted Guide Filtering Demosaicing Method with Weighting Coefficients Based on RGB-NIR Filter Array[J]. Acta Photonica Sinica, 2024, 53(9): 0911003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Feb. 2, 2024

    Accepted: Mar. 28, 2024

    Published Online: Nov. 13, 2024

    The Author Email: Xibin YANG (yangxb@sibet.ac.cn)

    DOI:10.3788/gzxb20245309.0911003