Optics and Precision Engineering, Volume. 33, Issue 6, 850(2025)

Double-specular-surface metrology by common benchmark calibration method

Wenjing HE1, Yubo NI1, Nan GAO1, Zhaozong MENG1, Zeqing YANG1, Guofeng ZHANG2, Wei YIN3, Hongwei ZHAO2,3, and Zonghua ZHANG1、*
Author Affiliations
  • 1School of Mechanical Engineering, Hebei University of Technology, Tianjin30040, China
  • 2School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an710049, China
  • 3National Key Laboratory of Strength and Structural Integrity,Aircraft Strength Research Institute of China, Xi'an710065, China
  • show less
    Figures & Tables(11)
    Schematic of double-specular-surface metrology by common benchmark calibration method
    Calibration plates for calibration
    Spatial location relationships between coordinate systemOA-XAYAZA and coordinate system OB-XBYBZB
    Spatial constraint between the two surfaces of the double-specular-surface calibration plate and the two cameras
    Experimental system
    Experimental results of the steps
    Experimental results of the measuring block obtained by calibrating the common benchmark parameters using dimensional parameters of double-specular-surface calibration plate
    Experimental results of the measuring block obtained by calibrating the common benchmark parameters using spatial constraint relations
    • Table 1. Euler angle and angle difference between RPA and LCDA1

      View table
      View in Article

      Table 1. Euler angle and angle difference between RPA and LCDA1

      VariablePitch angleYaw angleRoll angle
      RPA2.063 010.783 74.237 2
      LCDA12.067 910.781 94.246 3
      Difference0.004 90.001 80.009 1
    • Table 2. Euler angle and angle difference between RPB and LCDB1

      View table
      View in Article

      Table 2. Euler angle and angle difference between RPB and LCDB1

      VariablePitch angleYaw angleRoll angle
      RPB0.755 01.444 23.437 1
      LCDB10.761 91.438 23.432 7
      Difference0.006 90.006 00.004 4
    • Table 3. Errors in the 3D metrology of the measuring block under different calibration methods of common benchmark parameters

      View table
      View in Article

      Table 3. Errors in the 3D metrology of the measuring block under different calibration methods of common benchmark parameters

      Calibration methodRMSEPV
      Based on dimensional parameters0.1640.362
      Based on spatial constraint relations0.0760.207
    Tools

    Get Citation

    Copy Citation Text

    Wenjing HE, Yubo NI, Nan GAO, Zhaozong MENG, Zeqing YANG, Guofeng ZHANG, Wei YIN, Hongwei ZHAO, Zonghua ZHANG. Double-specular-surface metrology by common benchmark calibration method[J]. Optics and Precision Engineering, 2025, 33(6): 850

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Nov. 8, 2024

    Accepted: --

    Published Online: Jun. 16, 2025

    The Author Email:

    DOI:10.37188/OPE.20253306.0850

    Topics