Chinese Journal of Lasers, Volume. 50, Issue 7, 0708009(2023)

Multi-Filament Interaction Induced Breakdown Spectroscopy for Trace Element Detection in Soil

Yu Qiao1, Mengyun Hu1,2,3、*, Jinman Ge4, Fangfang Li1,2, Shupeng Xu1,2, Ming Yan1,2, Xiaojun Li4, and Heping Zeng1,2
Author Affiliations
  • 1State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062, China
  • 2Chongqing Key Laboratory of Precision Optics, Chongqing Institute, East China Normal University, Chongqing 401120, China
  • 3ROI Optoelectronics Technology Co., Ltd., Shanghai 201108, China
  • 4National Key Laboratory of Science and Technology on Space Microwave, China Academy of Space Technology (Xi an), Xi an 710100, Shaanxi, China
  • show less
    Figures & Tables(8)
    System diagrams. (a) Diagram of experimental setup; (b) schematic of FIBS system; (c) schematic of GIBS system; (d) schematic of TIBS system
    Spectral lines of chromium at 425.48, 427.54, and 429.03 nm for different systems
    Evolutions of spectral intensity and SNR of Cr I 429.03 nm characteristic peak with detection delay
    Cr I 427.54 nm spectral line signals at different sample locations in different systems. (a) FIBS system; (b) GIBS system; (c) TIBS system
    Calibration curves of chromium elements in different systems. (a) FIBS system; (b) GIBS system; (c) TIBS system
    • Table 1. Spectral parameters of Cr I lines

      View table

      Table 1. Spectral parameters of Cr I lines

      PositionAki /(107 s-1TransitionEi /cm-1Ek /cm-1JiJk
      Cr I 425.48 nm3.153d56S3)4s→3d56S4)4p023498.815634
      Cr I 427.54 nm3.073d56S3)4s→3d56S3)4p023386.341933
      Cr I 429.03 nm3.163d56S3)4s→3d56S2)4p023305.002632
    • Table 2. Spectral line signal intensity of FIBS, GIBS, TIBS systems at Cr I 425.48 nm,Cr I 427.54 nm, and Cr I 429.03 nm and signal enhancement among different systems

      View table

      Table 2. Spectral line signal intensity of FIBS, GIBS, TIBS systems at Cr I 425.48 nm,Cr I 427.54 nm, and Cr I 429.03 nm and signal enhancement among different systems

      PositionIFIBSIGIBSITIBSEGIBSETIBS
      Cr I 425.48 nm378511355315653.02.8
      Cr I 427.54 nm278611545342774.13.0
      Cr I 429.03 nm345413486427463.93.2
    • Table 3. Average relative errors of different systems for testing samples with different chromium contents

      View table

      Table 3. Average relative errors of different systems for testing samples with different chromium contents

      System

      Chromium mass fraction of

      342×10-6

      Chromium mass fraction of

      684×10-6

      Chromium mass fraction of 1368×10-6Chromium mass fraction of 2052×10-6Chromium mass fraction of 2736×10-6Chromium mass fraction of 3420×10-6
      FIBS2.736.559.986.721.882.38
      GIBS5.803.185.421.843.172.26
      TIBS6.801.681.080.940.720.46
    Tools

    Get Citation

    Copy Citation Text

    Yu Qiao, Mengyun Hu, Jinman Ge, Fangfang Li, Shupeng Xu, Ming Yan, Xiaojun Li, Heping Zeng. Multi-Filament Interaction Induced Breakdown Spectroscopy for Trace Element Detection in Soil[J]. Chinese Journal of Lasers, 2023, 50(7): 0708009

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: nonlinear optics

    Received: Dec. 16, 2022

    Accepted: Feb. 24, 2023

    Published Online: Apr. 14, 2023

    The Author Email: Hu Mengyun (myhu@phy.ecnu.edu.cn)

    DOI:10.3788/CJL221538

    Topics