Acta Optica Sinica, Volume. 43, Issue 13, 1312005(2023)

Trace Hazardous Substance Detection Based on Long-Distance Laser Vibrometer

Xiaoli Liu, Ziwei Wang, and Yu Fu*
Author Affiliations
  • Shenzhen Key Laboratory of Intelligent Optical Measurement and Detection, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, Guangdong, China
  • show less
    Figures & Tables(7)
    CW and pulse output power of MINI-QCL
    CW and pulse output power of MIRcat-1200-1824 QCL
    LDV device. (a) Schematic of LDV optical design; (b) LDV real scene
    Experimental setup. (a) Experimental setup at distance of 200 m; (b) LDV experimental setup on the other end
    Schematic of the pipeline leakage experiment setup
    Comparison of experimental result with infrared absorption spectrum. (a) Infrared absorption spectrum of PTFE provided by NICODOM company; (b) normalized vibration amplitude obtained by LDV at different wavenumbers
    Comparison of experimental result with infrared absorption spectrum. (a) Infrared absorption spectrum of acetone measured by a spectrometer; (b) normalized vibration amplitude of acetone obtained by LDV at different wavenumbers
    Tools

    Get Citation

    Copy Citation Text

    Xiaoli Liu, Ziwei Wang, Yu Fu. Trace Hazardous Substance Detection Based on Long-Distance Laser Vibrometer[J]. Acta Optica Sinica, 2023, 43(13): 1312005

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Apr. 17, 2023

    Accepted: May. 29, 2023

    Published Online: Jul. 12, 2023

    The Author Email: Fu Yu (fuyuoptics@gmail.com)

    DOI:10.3788/AOS230829

    Topics