Chinese Journal of Lasers, Volume. 34, Issue 9, 1255(2007)

Dynamic Measurement of Small Angle with Two Prisms

[in Chinese]1,2、*, [in Chinese]1, [in Chinese]1,2, [in Chinese]1, and [in Chinese]1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(12)

    [1] [1] P. R. Yoder, J. E. Schlesinger, J. L. Chickvary. Active annular-beam laser autocollimator system [J]. Appl. Opt., 1975, 14(8):1890~1895

    [2] [2] I. K. Ilev. Fiber-optic autocollimation refractometer [J]. Opt. Commun., 1995, 119(5-6):513~516

    [3] [3] P. S. Huang, S. Kiyono, O. Kamada. Angle measurement based on the internal reflection effect: a new method [J]. Appl. Opt., 1992, 31(28):6047~6055

    [5] [5] Yu. V. Filatov, D .P. Loukianov, R. Probst. Dynamic angle measurement by means of a ring laser [J]. Metrologia, 1997, 34(4):343~351

    [6] [6] R.Torroba, A. A. Tagliaferri. Precision small angle measurements with a digital Moiré technique [J]. Opt. Commun., 1998, 149(4-6):213~216

    [7] [7] M. Ikram, G. Hussain. Michelson interferometer for precision angle measurement [J]. Appl. Opt., 1999, 38(1):113~120

    [8] [8] J. H. Zhang, C. H. Meng. A linear/angular interferometer capable of measuring large angular motion [J]. Meas. Sci. Technol., 1999, 10(12):1247~1253

    [9] [9] Zhang Caini, Wang Xiangzhao. Sinusoidal phase-modulating laser diode interferometer for measuring angular displacement [J]. Opt. Eng., 2004, 43(12):3008~3013

    [10] [10] P. Shi, E. Stijns. New optical method for measuring small-angle rotations [J]. Appl. Opt., 1988, 27(20):4342~4344

    [13] [13] O. Sasaki, T. Okamura, T. Nakamura. Sinusoidal phase modulating Fizeau interferometer [J]. Appl. Opt., 1990, 29(4):512~515

    [14] [14] O. Sasaki, H. Okazaki. Analysis of measurement accuracy in sinusoidal phase modulating interferometry [J]. Appl. Opt., 1986, 25(18):3152~3158

    CLP Journals

    [1] Li Suning, Zhu Rihong, Shen Hua. Correction Effect to Spectral Resolution of Spectrometer Caused by Counter Rotating of Sagnac Prism[J]. Chinese Journal of Lasers, 2010, 37(3): 652

    [2] Wang Dahui, Zhao Jun, Zhao Xueqing, Zhang Yongsheng, Hu Yun, Hua Hengqi, Zheng Guoxin, Xue Quanxi. Measurement and Analysis on Structure Stability of Optical Mirror Mounts with Small Aperture[J]. Chinese Journal of Lasers, 2010, 37(S1): 308

    [3] Wu Xiang, Liao Wei, Liu Jin′gao. A Naked-Eye Stereoscopic Display System Based on Digital Light Processor[J]. Chinese Journal of Lasers, 2009, 36(2): 417

    [4] Wu Zhengang, Zeng Zhoumo, Li Xingqiang, Wu Xiangyu, Fu Luhua. Non-Contact In-Situ Dihedral Angle Measuring Approach Base on Rotary Ray-Scanning Mechanism[J]. Chinese Journal of Lasers, 2016, 43(5): 508001

    [5] Fang Guanming, Cao Yiping, Zhou Liping. Analysis on the Position Sensitive Detector Positioning Error Caused by Laser Spot Using New Three-Ray Model[J]. Chinese Journal of Lasers, 2009, 36(4): 954

    [6] Gong Zhihua, Chen Min, Wang Yong, Yan Rui, Tai Renzhong. Measurement of Monochromator′s Angle Repeatability by Phase Plate Diffraction Collimation Method[J]. Acta Optica Sinica, 2009, 29(10): 2813

    [7] Zhu Guangzhi, Zhu Xiao, Zhu Changhong, Qi Lijun. Ray Transmission Characteristics of Off-Axis Prism-Pair[J]. Chinese Journal of Lasers, 2009, 36(8): 2019

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Dynamic Measurement of Small Angle with Two Prisms[J]. Chinese Journal of Lasers, 2007, 34(9): 1255

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Measurement and metrology

    Received: Dec. 18, 2006

    Accepted: --

    Published Online: Oct. 17, 2007

    The Author Email: (defeng2003@mail.siom.ac.cn)

    DOI:

    Topics